The Nova Series Reduced Clearance Kit is installed to receive lower back wall clearance to 

combustibles. This Owner’s Manual is intended for use as a supplement to: 

-  Nova and Nova Tower Owner’s Manual, or 

-  Nova 2 and Nova 2 Tower Owner’s Manual 

 

If any portions of the Nova Series Reduced Clearance Kit are damaged or removed, the 

stove cannot be operated unless clearance to combustibles are re-evaluated based on 

guidance in the respective product Owner’s Manual. Failure to follow all clearance to 

combustible requirements may result in property damage, damage, bodily injury, or even 

death. 

Top vent, ceiling exit

 

 

 

   

Nova, Nova Tower 

Double Wall Connector Pipe 

with Reduced Clearance Kit

 

Nova 2, Nova 2 Tower 

Double Connector Pipe with 

Reduced Clearance Kit 

A

 

Sidewall to unit

 

20” (508 mm)

 

22” (559 mm) 

B

 

Backwall to unit

 

7.5” (191 mm)

 

9” (229 mm) 

C

 

Sidewall to connector

 

28” (711 mm)

 

31” (787 mm) 

D

 

Backwall to connector

 

13” (330 mm)

 

12.5” (318 mm) 

 
 
 
 