Version: 18/10/2016
Filename: NA-MHF-22-COD-E_version3.doc
© Meyrat SA 2017
7 / 25
Air-oil lubrication
Item no. of unit
Item no. of doser unit
DLB-SF3BNCDA
DLB-AVx
Pressure in spindle entry
0.6 to 0.7 bar
Air quality
DIN ISO 8573.1:2001 Class 3
Oil
Motorex COREX HLP ISO VG 68
Regulation of oil flow
30mm
3
per hour
Recommended volume of doser
10 mm
3
Pneumatic tube
ø6/4, length 2m to 5m *
Accessories included with the group
4 liters of Motorex COREX HLP ISO VG 68
* The
first 10 cm of tube are ø4/2.5. The length of 10 cm should not be exceeded.
!
ATTENTION!
Without a right lubrication, the spindle will be damaged very fast. It is better
to use a coil at the proximity of spindle; to create an oil reserve in case of pressure is
disabled.
!
ATTENTION!
The air pressure must be enabled / disabled at the same time that the
lubricants pump.
This kind of lubrication requires a stable and continuous in time functioning to establish a
steady oil flow in the tube. Thus, frequent interruptions of lubrication and air pressure are
not allowed. Lubrication must be active during periods of at least 1 hour.
!
ATTENTION!
A too short length of tube will not allow the oil to create a continuous flow in
the tube. It will thus not be possible to guarantee a constant arrival of oil lubrication
between two pulses.
!
ATTENTION!
O
nly one spindle can be connected to each doser output. With multiple
connections, it is not possible to guarantee the quality or quantity of lubrication on each
spindle.
For settings and connections on the air-oil lubrication units, please refer to the assembly instructions of
the device.
2.3 Frequency converter
Item no.:
CFB-MHF500
Interface
front panel / D-Sub 15 pins connector
Power supply
110-230 VAC
Dimensions (length x width x height)
220 x 105 x 105 mm
Weight
2.2 kg
!
ATTENTION!