-5-
Test Mode
Clip-on CT, integral mode
Display Mode
Four digits LCD display
LCD
Dimension
35mm×21.5mm
;
display domain
:
32mm×15mm
Frequency
AC 45Hz~400Hz
Sampling
Rate
2 times/s
Polarity
Indication
DC current auto identified and display“
—
”
Test Position
Tested wire in the jaw center; Error will increase to
1.5%rdg max if deviate the center
Range Shift
Automatically
Line Voltage
AC600V
Software
with the software the data can upload to computer
Data Memory
99units
,
FULL blinks when the memory is full
Peak Hold
Push
HOLD
without release, the meter will show the
peak value during the pushing period
Reading Hold
DH
indicating the reading is hold
Out of Range
OL
indicating the current is out of range