1. 

USB data download interface 

2, 

3.5 inch color LCD screen 

3. 

Host 

4. 

Up and down arrow keys and 

MEM 

control keys

 

5. 

Host 

POWER 

button

 6.

 Detector probe hook (2pcs)

 

7. 

Detector probe (2pcs)

 8. X

 detector

 

9. 

Power indicator,

 10. 

Detector 

POWER 

button

 

11. 

Detector insulation rod interface

 12. 

Working signal indicator   

13. 

Detector battery bottom cover

 14. Y 

detector

 

15.

 Telescopic insulation rod (2pcs) 

 

VII

Operation 

 

 

Please  check  all  parts  of  the  meter  carefully 
before  usage,  to  see  whether  there  is  any 
damage.  And  make  sure  no  damage  before 
usage.

   

According  to  manual  instructions  to  install  the 
battery

 

 

1. Host Power On/Off 

Press 

POWER

  button  to  power  on,  the  instrument  will 

displays  the  LCD  screen,  Press 

POWER

  button  to  power  off.  If 

LCD  display  is  relatively  dark  after  power  on,  it  is  possible  that 
battery  voltage  is  low.  Please  replace  battery.  5  minutes  after 
powering  on  the  meter,  if  it  remains  idle,  an  auto-power  off 
procedure starts to preserve the battery life and LCD will continue 
flash until the complete switch off takes place after 30 seconds. In 
case  of  LCD  continuous  flash,  press 

POWER

  button,  then  the 

meter will continue to work.   
2. Detector Power ON/OFF 

Press  the 

POWER

  button  to  turn  on,  the  POWER  indicator 

light, the detector into the test mode, and then press the 

POWER

 

Summary of Contents for MEWOI2600

Page 1: ...Wireless High Voltage Phase Detector MEWOI2600 User Manual www mewoi com...

Page 2: ......

Page 3: ...cture 6 V Operation 7 1 Host Power On Off 7 2 Detector Power On off 7 3 Data Maintenance 8 4 Data Memory 8 5 Data Reference 8 6 Data Deletion 9 7 LCD Screen 9 8 Data Transmission 9 9 Self checking 9 1...

Page 4: ...oltage of tested circuitry has exceeded 400V it must be used by connecting with an insulation rod As it is very dangerous of high voltage transmission line the operator must get strict training and th...

Page 5: ...y danger may occur if continue to use it stop using it immediately and seal it up for keeping at once which shall be dealt with by qualified authorization agency The danger symbol on the meter and the...

Page 6: ...he electricity and judging transformer groups MEWOI2600 wireless high voltage phase detector is composed of a host machine detector telescopic rod insulation monitoring software USB communication line...

Page 7: ...ector Zinc manganese dry batteries 6F22 9V Phase Detect Modes 1 Contact Phase Detect can contact wire which is below 35KV bare wire or 220KV With insulation Cover 2 Non Contact Phase Detect conduct no...

Page 8: ...c shut down Turn on the instrument for about 5 minutes Battery Voltage When the battery voltage dropped to 7 2V 0 1V the battery voltage is low symbol display to remind the replacement of the battery...

Page 9: ...ral technical requirements for portable nuclear power apparatus for use in 1kV 35kV portable power plants DL T971 2005 IEC61481 A2 2004 IEC 61243 1 ed 2 2003 Accessories Host 1set Detector 2 pieces Pr...

Page 10: ...cording to manual instructions to install the battery 1 Host Power On Off Press POWER button to power on the instrument will displays the LCD screen Press POWER button to power off If LCD display is r...

Page 11: ...on again to release data lock returning to normal testing mode and HOLD symbol disappears Data Storage Data Reference 4 Data Memory Under normal testing mode press Left Arrow to hold and store the dat...

Page 12: ...LCD backlight is automatically stored and the stored brightness value is automatically restored when the instrument is turned on 8 Data Upload Connect the computer and the host USB communication line...

Page 13: ...onal injury or damage to equipment Cannot be used to test more than 220kV voltage line otherwise there is an electric shock causing personal injury or equipment damage The high voltage test must be co...

Page 14: ...etal hook detector into metal probe Non contact phase detection If the lines are relatively close to each other should test the position of the wire where is far away from the other wires Phase detect...

Page 15: ...ough Please replace the battery in time 1 When the battery voltage is below 7 2V 0 1V the meter will display symbol the power indicator flashing Indicates that the battery is low Please replace batter...

Page 16: ...If not please repeat the operation according the step 2 IX Accessories Host 1pcs Detector 2pcs Detector Probe Hook Probe 2pcs each Calibration line 1pc USB Cable 1pc Monitoring software CD 1pc Bag 1se...

Page 17: ...Your Testing Specialist...

Reviews: