8. Connection examples

Connection examples 1 and 2

11

44

C1

C1

C1

C1

12

12

22

22

22

33

C1

C1

C1

C1

1111

21

21

14

14

24

24

11

22

33

44

24V

24V

24V

24V

+24V

+24V

GND

GND

+24V

+24V

GND

GND

ERROR

ERROR

B +

B +
A

A --

MR-DIO4/2

MR-DIO4/2

B +

B +
A

A --

BUSY

BUSY

x1

x1

x10

x10

MODBus RTU

MODBus RTU

A1 (24 V

A1 (24 VA

AC/DC)

C/DC)

N

N
LL

Jumper unter

Jumper unter

der Blende

der Blende

Connection example 3

A2 (GND)

A2 (GND)

N

N
LL

11

44

C1

C1

C1

C1

12

12

22

22

22

33

C1

C1

C1

C1

1111

21

21

14

14

24

24

11

22

33

44

24V

24V

24V

24V

+24V

+24V

GND

GND

+24V

+24V

GND

GND

ERROR

ERROR

B +

B +
A

A --

MR-DIO4/2

MR-DIO4/2

B +

B +
A

A --

BUSY

BUSY

x1

x1

x10

x10

MODBus RTU

MODBus RTU

Jumper unter

Jumper unter

der Blende

der Blende

5

6

The  module  can  be  aligned  without  interspace.  Use  the  jumper

plug  to  connect  bus  and  supply  voltage  when  the  modules  are

mounted in series.

The maximum quantity of modules connected in line is limited

to 15 or to a maximum power consumption of 2 Amps (AC or

DC) per connection to the power supply. For any similar block

of  additional  modules  a  separate  connection  to  the  power

supply is mandatory.

Mounting in series

7. Bit rate and Parity setting

The bit rate and parity can be set in the programming mode when

ajumper  is  plugged  behind  the  front  cover  of  the  module.  This

jumper is removed in normal mode. A connection to the bus is not

required during bit rate setting.
The bit rate of the modules can be set in the following way: 
1.    remove the front cover of the module; 
2.    plug  a  jumper  to  the  two  middle  pins  of  the  4  pole  header 

between the red and green LED (

Á

);

3.    set the desired parity and bit rate with the address switches

(

Â

) in accordance to the chart below.

4.    switch on the supply voltage of the module; it is now perma-

nently saving the bit rate in an EEPROM;

5.    switch off the supply voltage of the module;
6.    remove the jumper from the header and place the front cover.

If the settings differ from the settings specified in the chart the

factory setting applies.

Factory setting: 19200 Bd Even

1

1

44

C1

C1

C1

C1

12

12

22

22

22

33

C1

C1

C1

C1

1111

21

21

14

14

24

24

1

1

22

33

44

24V

24V

24V

24V

+24V

+24V

GND

GND

+24V

+24V

GND

GND

ERROR

ERROR

B +

B +
A

A --

MR-DIO4/2

MR-DIO4/2

B +

B +
A

A --

BUSY

BUSY

x1

x1

x10

x10

MODBus RTU

MODBus RTU

JJ

+24V

+24V

GND

GND

Jumper below

Jumper below

the faceplate

the faceplate

Á

Á

Â

Â

Switch

x1

0

1

2

3

4

5

6

7

Bitrate

(Bit/s) 1200 2400 4800 9600 19200 38400 57600 115200

Switch

x10

0

1

2

Parity even odd none

9. Software description

9.1 I/O Commands

"01 (0x01) Read Coils"

Request

    Valid Starting Address          0 .. 3

    Valid Quantity of Outputs    1 .. 4

Response

    Byte Count                           1

    Output Status                      Bit0 .. Bit3 (Bit 4 .. 7=0)

Bit

Information

0

0 = Status relay 1 off

1 = Status relay 1 on

1

0 = Status relay 2 off

1 = Status relay 2 on

2

0 = relay 1 switched via bus

1 = relay 1 switched via manual control

3

0 = relay 2 switched via bus

1 = relay 2 switched via manual control

"02 (0x02) Read Discrete Inputs"

Request

    Valid Starting Address          0 .. 3
    Valid Quantity of Inputs       1 .. 4

Response

    Byte Count                           1
    Input Status                         Bit0 .. Bit3 ( Bit 4 .. 7 = 0 )

Information

    1= Status input closed
    0= Status input open

“05 (0x05) Write Single Coil”

Request

    Valid Output Address           0 .. 1
    Valid Output Value               0x0000 or 0xFF00

Response

    Echo of the request

“15 (0x0F) Write Multiple Coils”

Request

    Valid Starting Address          0 .. 1
    Valid Quantity of Outputs    1 .. 2
    Valid Byte Count                  1
    Output Value                        0 or 1 in Bit0 .. Bit1

Bit

Information

0

0 = Status relay 1 off

1 = Status relay 1 on

1

0 = Status relay 2 off

1 = Status relay 2 on

Response:                                  Function Code, Starting Adress,

                                                 Quantity of Outputs

BTR NETCOM GmbH

Im Tal 2
78176 Blumberg
Germany

Phone +49 7702 533-0
Fax     +49 7702 533-189

Mounting instruction see
www.metz-connect.com

2

1

6. Mounting

Power down the equipment

Mount  the  module  on  standard  rail  (TH35  per  IEC  60715  in 

junction boxes and/or on distribution panels).

Installation
Electric  installation  and  device  termination  shall  be  done  by

qualified  persons  only,  by  respecting  all  applicable 

specifications and regulations.

Plug in the terminal block for bus connection

4

3

5 mm

Connect the cable for bus supply

Summary of Contents for Logline MR-DIO4/2

Page 1: ... DC High Signalerkennung 8 V AC DC Ausgangsseite Ausgangskontakte 2 Wechslerkontakte Schaltspannung max 250 V AC Dauerstrom max 16 A Relais 80 A 20 ms Summenstrom über alle Kontakte 25 A Gehäuse Abmessungen BxHxT 50 x 70 x 75 mm Gewicht 126 g Einbaulage beliebig Montage Tragschiene TH35 nach IEC 60715 Anreihbar ohne Abstand Nach dem Anreihen von 15 Modulen oder einer maximalen Stromaufnahme von 2 ...

Page 2: ...GND 24V 24V GND GND ERROR ERROR B B A A MR DIO4 2 MR DIO4 2 B B A A BUSY BUSY x1 x1 x10 x10 MODBus RTU MODBus RTU A1 24 V A1 24 VA AC DC C DC N N L L Jumper unter Jumper unter der Blende der Blende Anschlussbeispiel 3 A2 GND A2 GND N N L L 1 1 4 4 C1 C1 C1 C1 12 12 22 22 2 2 3 3 C1 C1 C1 C1 1 11 1 21 21 14 14 24 24 1 1 2 2 3 3 4 4 24V 24V 24V 24V 24V 24V GND GND 24V 24V GND GND ERROR ERROR B B A A...

Page 3: ...Modbus Kommando Parität und Bitrate haben die gleichen Werte wie bei der Einstellung über die Adressschalter Wenn Parity oder Baud 0 ist erfolgt keine Einstellung und Speicherung Der Registerinhalt wird im EEPROM gespeichert 06 0x06 Write Single Register Request Valid Register Address 0x41 65 Valid Register Value 2 Bytes Bit 15 8 Magic Number 0x53 83 zum Schutz vor versehent lichem Schreiben Nur m...

Page 4: ...t for all contacts 25 A Housing Dimensions WxHxD 2 0 x 2 8 x 3 0 in 50 x 70 x 75 mm Weight 126 g Mounting position any Mounting standard rail TH35 per IEC 60715 Mounting in series the maximum quantity of modules without space connected in line is limited to 15 or to a maximum power consumption of 2 Amps AC or DC per connection to the power supply For any similar block of additional modules a separ...

Page 5: ...ttings specified in the chart the factory setting applies Factory setting 19200 Bd Even 1 1 4 4 C1 C1 C1 C1 12 12 22 22 2 2 3 3 C1 C1 C1 C1 1 11 1 21 21 14 14 24 24 1 1 2 2 3 3 4 4 24V 24V 24V 24V 24V 24V GND GND 24V 24V GND GND ERROR ERROR B B A A MR DIO4 2 MR DIO4 2 B B A A BUSY BUSY x1 x1 x10 x10 MODBus RTU MODBus RTU J J 24V 24V GND GND Jumper below Jumper below the faceplate the faceplate Á Á...

Page 6: ...as returned no response neither a normal response nor an exception response since its last restart clear counters operation or power up Continuation Software description 9 2 Bit rate setting with Modbus command Parity and bit rate have the same value as when setting them by address switch If Parity or Bit has the value 0 no setting or storage is carried out The register content is stored in the EE...

Reviews: