6 N1 70 en
5
1.7
Safety precautions
WARNING:
Valve on which actuator is installed should be earthed
properly to discharge static charge.
2
TRANSPORTATION AND STORAGE
Make sure that the actuator and associated equipment
have not been damaged during transportation. Store the
actuator carefully before installation, preferably indoors in a
dry place. Do not take it to the installation site or remove
the protective caps of ports for piping until just before
installation.
Lift the actuator as shown in Fig. 5: in a horizontal position
from the lifting lugs. Refer to Section 9 for weights..
Fig. 5
Lifting the actuator
Upon receiving the product check the limit actuator and
the accompanying devices for any damage that may have
occurred during transport.
Store the actuator carefully. Storage indoors in a cool, dry
place. Temperature limit for the storing is from 4 °C to 40 °C.
The actuator should be left in its original packing until it is
required for the use. Do not remove protective plugs until
installing the actuator.
NOTE:
Advisory and information comments provided to assist
maintenance personnel to carry out maintenance proce-
dures.
WARNING FOR ATEX:
If not observed, user incurs a high risk of severe dam-
age to actuator and/or fatal injury to personnel.
CAUTION:
Don’t exceed the permitted values!
Exceeding the permitted pressure value marked on the
actuator may cause damage and lead to uncontrolled
pressure release in the worst case. Damage to the equip-
ment and personal injury may result.
CAUTION:
Don’t dismantle a pressurized actuator!
Dismantling a pressurized actuator leads to uncontrolled
pressure release. Shut off the supply pressure and release
pressure from the cylinder before dismantling the actua-
tor. Otherwise, personal injury and damage to equipment
may result.
CAUTION:
Follow the instructions given on the actuator warning
plates!
CAUTION:
Before opening the cylinder fastening screws (11),
release spring tension directed on actuator warning
plate and in these instructions!
CAUTION:
Don’t dismantle the spring module!
Do not remove the spring module while the spring is com-
pressed or under pressure.
CAUTION:
Take the weight of the actuator or valve combination
into account when handling it!
Lifting lugs on the actuator are meant only for lifting
actuator and not complete valve assembly.
Do not lift the valve combination from the actuator, posi-
tioner, limit switch or their piping. Lift the actuator as
directed in Section 2, lifting ropes for a valve combination
should be fastened around it. The weights are shown in
Section 9. Dropping may result in personal injury or dam-
age to the equipment.
WARNING FOR ATEX:
While lifting actuator housing should not
impact on the other light or rusty metal .
CAUTION:
Potential electrostatic charging hazard, do not rub
surface with dry cloth.
WARNING FOR ATEX:
Inspect for paint damaged, to ensure contin-
ued corrosion protection.
Actuator speed should not faster than speci-
fied in the following chart.
MODEL
STROKE
(mm)
MINIMUM
OPENING/CLOSING
TIME (SECONDS)
N1X
56
0.1
N1A
116
0.1
N1B
150
0.2
N1C
180
0.2
N1D
216
0.3
N1E
260
0.3
N1G
320
0.4
N1H
396
0.5
WARNING:
DO NOT USE THE DEVICE IF IT IS DAMAGED
DURING TRANSPORTATION!
IF THE DEVICE HAS SUFFERED DAMAGE DUR-
ING TRANSPORTATION DO NOT INSTALL AND USE IT.
IN CASE OF NOTICING DAMAGE TO THE DEVICE UPON
RECEIVING IT PLEASE CONTACT THE SUPPLIER.
Summary of Contents for Neles N1 Series