23
Note: This method will work only if there is no cross bonding on the length of the conductor between the
conductor and the receiver.
Figure 4-11: Position of Metroclamps When Using Two
4.9 Marking the Conductor
The following color markings have been established by the American Public Works Association (APWA):
Conductor
Color
electric power lines, cables, or conduits
red
communication lines, cables, conduits, CATV
orange
gas, oil, petroleum, or other gaseous materials
yellow
storm and sanitary sewers, drain lines
green
water, irrigation, or slurry lines
blue
Note: If you have any questions regarding marking requirements or procedures, please call your local One
Call Center
5 TRACING FACTORS AND HELPFUL INFORMATION
Many variables affect the process of locating a pipe or cable. The following information gives guidelines
for various problem situations.
5.1 Soil Conditions
Generally, the effect of soil types on line tracing is as follows: