17
If no direct connect cable or Metroclamp is attached to the DIRECT/4820 CLAMP jack, the transmitter
automatically broadcasts the signal through the antenna mounted on the transmitter case.
No ground connection is needed when a signal is induced onto the target conductor.
SAFETY WARNING
Do not operate the Transmitter in the Inductive Mode while it is resting on or near a metal surface or large
metal object. Incorrect test readings and damage to the transmitter may result.
1 Position the transmitter over the buried conductor making sure that the transmitter is parallel or in line
directly over the targeted conductor.
2 When using the Inductive method, the receiver must be 35-50 ft. away from the transmitter depending on
how high the sensitivity is set. The higher the sensitivity, the farther from the transmitter the receiver must
be to avoid picking up the transmitter signal traveling through the air.
3 Continue your locate by following steps 4 through 11, Section 4.1 Direct Connection.
4.4 480B 50/60Hz Power Line Locating
When locating a power line the 480B Transmitter is not required as you are locating the power line by
tracking the path of the 50/60 current coming off the line (the line must be loaded).
This method gives a maximum (loud tone) signal. The 480B Receiver is held in a vertical position at right
angles to the line for maximum signal. (Note the logical path of the line from the source).
You will notice a difference audio tone when using the 50/60Hz mode, this is normal.
50/60 Power Line Locating Operation:
1
Move the 480B Receiver a few feet away from where you want to start searching.
2
Turn the Receiver MODE Switch to “Passive 50/60Hz”.
3
Hold the Receiver in a vertical position. Then adjust the SENSITIVITY knob to bring the needle
within the “SET” zone. If the meter does not adjust to “SET”, turn the SENSITIVITY knob all
the way to the right (clockwise) and/or move closer to the conductor. If you still cannot adjust to
the “SET” position, switch the RANGE knob to “HIGH”:, and then attempt to adjust the
SENSITIVITY to “SEY”. (If no current is present you will be unable to adjust to “SET”).
4
Hold the Receiver in an upright, vertical position with the face of the Receiver facing you, and at
right angles to the targeted conductor.
5
Move the Receiver from side to side over the targeted conductor location until you obtain the
maximum PEAK response. For better signal reception, hold the Receiver close to the ground. As
you move closer to the targeted conductor, the speaker tone will gradually get louder. The loudest
tone will indicate you are over the conductor in the PEAK mode.