Ion Technologies MSE50V
Sewage Pump
OPERATION MANUAL
Dated: 03/30/2020
Document Name: MSE50V_OM
Page 5 of 8
www.ionproducts.net
•
Impeller or volute openings are fully or partially
clogged. Remove pump and clean.
• Pump impeller is partially clogged with tar or
paint, causing motor to run slow and overload.
Remove pump and clean.
FUSE BLOWS OR CIRCUIT BREAKER TRIPS
WHEN PUMP STARTS
• Pump impeller is partially clogged causing motor
to run slow and overload. Remove pump and
clean.
•
Motor stator may be defective.
• Fuse size or circuit breaker may be too small.
(must be 15 amps).
•
Impeller or volute opening are fully or partially
clogged. Remove pump and clean.
MOTOR RUNS FOR A SHORT TIME, THEN STOPS
•
Inlet holes in pump base are clogged. Remove
pump and clean the openings.
• Pump impeller is partially clogged causing motor
to run slow and overload. Remove pump and
clean.
•
Motor stator may be defective.
•
Impeller or volute openings are fully or partially
clogged.
•
Remove pump and clean. Also clean the strainer
if one is installed.
ELECTRICAL PRECAUTIONS
WARNING:
Before servicing a pump, always
shut off the main power breaker and then
unplug the pump. Make sure you are not standing
in water and are wearing insulated protective sole
shoes, under flooded conditions. Contact your local
electric company or a qualified licensed electrician
for disconnecting electrical service prior to pump
removal.
P
erformance
S
PecificationS
15.91”
13.53”
10.4”
11.53”
2” NPT
15.91”
13.53”
10.4”
11.53”
2” NPT