Page 83
Figure 16:
Connecting a holding brake with high current draw (> 1A) to the device
The switching of inductive direct current via relay produces strong currents and
sparking. For interference suppression we recommend integrated RC suppressor
elements, for example by Evox RIFA, denomination: PMR205AC6470M022 (RC
element with 22
in series with 0.47 µF).
Product Manual „Servo drives ARS 2100 SE“