5
I
NTRODUCTION
MS2122
D
ESIGN
S
PECIFICATIONS
Design Specifications
Operational
Light Source: VLD 650 nm
Peak Laser Power: <2.2 mW
Horizontal Depth of Field: 0 mm - 152 mm (0”- 6”) for 0.33 mm (13 mil) bar code
Vertical Depth of Field: 0 mm - 216 mm (0”- 8.5”) for 0.33 mm (13 mil) bar code
Scan Speed: 6000 scans lines per second
No. of Scan Lines: 68 (40 horizontal / 28 vertical)
Motor Speed: 4800 / 6000 RPM
Min Bar Width: 0.152 mm (6.0 mil)
Decode Capability: All standard 1-D bar codes RSS-14, RSS-Expanded, and RSS-14 Limited
System Interfaces: RS232, Aux RS232, IBM468x/469x, USB (low speed and full speed), OCIA
Print Contrast: 35% minimum reflectance difference
No. Characters Read: up to 80 data characters (Maximum number will vary based on symbology and density)
Beeper Operation: 7 tones or no beep; 3 volume settings
Indicators (LED): Blue = laser on, ready to scan; White = good read, decoding
Mechanical
Length: MS2122 - 400 mm (15.75")
Width (below counter): MS2122 - 292 mm (11.5")
Depth (below counter): 100 mm (3.9")
Height (above counter): 181 mm (7.1")
Weight (with platter): MS2122 - 6.93 Kg (15.25 lbs.)
Electrical
Voltage Supply:
1.5A @ +5V / 1.5A @ +12V
Operating Power: 14.25 Watts
Standby Power: 3.25 Watts
Operating Current: 1A @ 5V / .75A @ 12V
Standby Current: .44A @ 5V / .08A @ 12V
DC Transformers: Class II; 5VDC @ 1.5A; 12 VDC @ 1.5A
For Regulatory Compliance Information refer to pages 43 - 45.
Environmental
Operating Temperature: 0°C to 40°C (32°F to 104°F)
IP Rating: IP 55
Storage Temperature: -40°C to 60°C (-40°F to 140°F)
Humidity: 5% to 95% relative humidity, non-condensing
Contaminants: Sealed to resist airborne particulate contaminants
Ventilation: None
required
Specifications subject to change without notice.