The ECO Xtreme Ped, ECO Euro Ped, ECO Wee Curve and 
ECO Euro Rad models have the option to be installed as 
“Direct Vent” appliances, thereby drawing all primary and 
secondary combustion air from outside the home. Once 
connected, this direct venting option ensures the air that 
is heated within the home, stays in the home improving 
efficiency and reducing fuel usage.

Note: Connection of the Metro’s direct vent inlet to outside the home 
is optional. If not connected these Direct Vent models still offer greatly 
improved performance and lower emissions due to the unique pre-heated 
air path for all primary and secondary combustion air that these models 
consume.

Direct Vent Options

Three “Direct Vent kits” are available to connect the ECO DV 
Metro to an air supply from outside the living environment of 
the home. The kits available include;

•   DV WALL kIT – For installations when the Metro is 

installed against an outside wall.

•   DV FLOOR kIT– For installations onto a floor which has a 

free air supply below it.

•   DV CEILING kIT– For installations when the Metro is 

installed against an internal wall and on a concrete floor

(DV Ceiling kit goes into the wall cavity, then up inside the wall into the 
ceiling cavity, where the air supply is drawn from)

Installing the Direct Vent Option

Remove the rear heatshield from the Metro wood fire by 
unscrewing the four self tapping screws illustrated in Diagram 
3 and proceed as follows;

1.   Remove the section of panel illustrated with a “hatch”, 

from the mid/bottom section of the rear heatshield. This 
section to be removed has been pre-punched and only 
requires a few small tabs to be cut.

2.   Take the “inlet spigot” supplied in the “Direct Vent kit” and 

slide it fully down into position into the brackets provided 
on the rear of the firebox.

3.   Replace the Metro’s rear heatshield with the four screws 

previously removed.

The Metro wood fire is now ready for installation once you 
have pre-fitted the Direct Vent kit into the wall or floor. Full 
instructions for this procedure are supplied with the Direct 
Vent kits.

Direct vent option

INLET SPIGOT

REAR 

HEAT SHIELD

Diagram 3

Summary of Contents for ECO Euro Ped

Page 1: ...pecifications 6 Wetback and flue installation 7 Operation important information 8 Where to install a Metro in your home 9 Optional wetbacks 9 Getting to know your Metro 10 Operating your Metro 10 Clea...

Page 2: ...Metro s be installed with a Metro ECO flue system which has been developed to enhance the performance of Metro wood fires Any alternative flue system must have a minimum flue pipe length of 4 2 metre...

Page 3: ...n the pedestal with its front facing over the 4 bolts and fit the washers and nuts supplied check to ensure the pedestal is correctly aligned and securely tighten the nuts It is recommended that 2 peo...

Page 4: ...ions onto a floor which has a free air supply below it DV CEILING KIT For installations when the Metro is installed against an internal wall and on a concrete floor DV Ceiling kit goes into the wall c...

Page 5: ...tector is on a concrete floor or coach bolts if a wooden floor secure through the holes provided at the base behind both rear legs Note the anchors must pass through the floor protector and securely a...

Page 6: ...hown are in mm with a Pioneer double flue shield fitted Model A B C D E F G H I J K L M ECO Tiny Rad 225 552 580 420 150 200 300 75 805 650 1165 925 250 ECO Tiny Ped 210 430 580 290 25 200 185 60 790...

Page 7: ...erence of the wetback which will face the inside rear wall of the firebox This will completely seal the wetback to the inside rear wall of the fire on installation 6 Fit the wetback into the firebox a...

Page 8: ...be operated with over worn faulty or missing door seals Door seals will harden over time and become over worn 3 4 year s this will cause air to leak into the fire causing the appliance to over fire It...

Page 9: ...r local territorial authority council you may or may not be able to install a water heating device If in doubt consult your local Metro retailer Water heating is another key feature of your Metro wood...

Page 10: ...the firebox Add dry kindling and move the air control knob fully to the right being the full open position Light the paper at two or three locations across the front of the door opening and leave the...

Page 11: ...moval The time this build up takes depends on the density and cleanliness of your fuel To remove the excess ash your Metro should not be operating Open the door and using a hearth shovel or similar em...

Page 12: ...but its starting too and is getting worse The pipe is in need of a clean It is recommended that the flue pipe to be cleaned every season however if you are burning the fire on low a lot or are using...

Page 13: ...een neglected by not being regularly maintained and serviced warranty may be declined It is critical that the fire not be operated with over worn faulty or missing door seals Door seals will harden ov...

Page 14: ...s renewable fuel is compressed into a dense pellet allowing for maximum heat to be released Check out Metro s new flame today Metro Solar Systems Metro Solar brings together Pioneer Manufacturing Ltd...

Page 15: ...od fire keeping it in good order for many years to come Pioneer heating accessories ECO Flue Systems Pioneer Flashrites Pioneer Versatiles Lead Aluminium Silicone Pioneer Fire Cement Pioneer Fireguard...

Page 16: ......

Reviews: