Metro Pedestal Fires

To minimise freight damage, the pedestal base has been 
packaged inside the firebox. Please note: you should only 
assemble this wood fire if you are suitably experienced in 
wood fire assembly and installation. 

To safely assemble your Metro, please proceed as follows: -

-  Safely remove straps by cutting straps with scissors.

-  Lift off carton, turn upside down (use to hold all discarded 

packaging).

-  Lift off the top grille and place somewhere safe. Be careful 

not to chip the enamel coating.

-  Open the door 90 degrees and lift the door off the hinge 

and place somewhere safe. Be careful not to chip the 
enamel coating.

-  Remove the pedestal packed in a cardboard wrap

-  Remove the pedestal mount plate

-  Remove pedestal heat shield (Xtreme & Euro models only)

-  Remove the side bricks, door handle and the bolt bag

-  Remove the 2 tek screws at the base of the inside of the 

firebox that are fixing the wood fire to the pallet.

-  It is recommended that 2 people work together with 

this step. Grab the underneath top of the firebox door 
opening with one hand, holding the flue spigot with the 
other, slowly lift the front of the wood fire all the way back 
and rest the wood fire on it’s rear heat shield on the floor. 
Remove the packaging pallet.

-  Xtreme & Euro models only – Fit the pedestal heat shield 

over the 4 bolts as shown in Diagram 1, with the open 
edge facing the front of the Metro (up)

-  Position the pedestal with its front facing over the 4 bolts 

and fit the washers and nuts supplied, check to ensure the 
pedestal is correctly aligned and securely tighten the nuts

-  It is recommended that 2 people work together with this 

step. Grab the flue spigot with one hand and the other 
hand underneath the top of the firebox door opening, lift 
upwards standing the wood fire onto it’s pedestal.

-  Re-fit the door and top grille

-  Open the door fully and fit the side bricks to each side of 

the fire box. Location lugs are fitted to the base and rear 
of the firebox to retain the side bricks in position. Refer to 
Diagram 2.

Note: The ECO Tiny Ped model utilises a slightly different pedestal to that 
detailed in Diagram 1. The rear panel on the pedestal must be turned 
around with the return fold facing back the opposite way.

All Metro Models

Check to ensure the top baffle is in its correct position in 
the top chamber of the firebox. It should be resting on four 
support lugs (two on each side of the firebox). The baffle must 
be hard back against the rear of the firebox with the “promet 
extension” (white board) or return front steel edge of the baffle 
facing forward as illustrated in Diagram 2.

TOP BAFFLE

COOk TOP 

GRILL

DOOR 

HANDLE

PEDESTAL

PEDESTAL 

HEAT 

SHIELD

PEDESTAL 

MOUNTING 

PLATE 

(NOT AVAILABLE 

ON TINY PED)

Diagram 1

(FOR EURO 

PED & XTREME 

PED ONLY)

Diagram 2

Assembling your Metro wood fire

Note: The ECO Wee Ped has an additional “3rd brick” which fits to the rear 
face of the firebox, locating under/into a bracket provided in the middle of 
the firebox’s rear face, under the top baffle.

SIDE BRICk

Summary of Contents for ECO Euro Ped

Page 1: ...pecifications 6 Wetback and flue installation 7 Operation important information 8 Where to install a Metro in your home 9 Optional wetbacks 9 Getting to know your Metro 10 Operating your Metro 10 Clea...

Page 2: ...Metro s be installed with a Metro ECO flue system which has been developed to enhance the performance of Metro wood fires Any alternative flue system must have a minimum flue pipe length of 4 2 metre...

Page 3: ...n the pedestal with its front facing over the 4 bolts and fit the washers and nuts supplied check to ensure the pedestal is correctly aligned and securely tighten the nuts It is recommended that 2 peo...

Page 4: ...ions onto a floor which has a free air supply below it DV CEILING KIT For installations when the Metro is installed against an internal wall and on a concrete floor DV Ceiling kit goes into the wall c...

Page 5: ...tector is on a concrete floor or coach bolts if a wooden floor secure through the holes provided at the base behind both rear legs Note the anchors must pass through the floor protector and securely a...

Page 6: ...hown are in mm with a Pioneer double flue shield fitted Model A B C D E F G H I J K L M ECO Tiny Rad 225 552 580 420 150 200 300 75 805 650 1165 925 250 ECO Tiny Ped 210 430 580 290 25 200 185 60 790...

Page 7: ...erence of the wetback which will face the inside rear wall of the firebox This will completely seal the wetback to the inside rear wall of the fire on installation 6 Fit the wetback into the firebox a...

Page 8: ...be operated with over worn faulty or missing door seals Door seals will harden over time and become over worn 3 4 year s this will cause air to leak into the fire causing the appliance to over fire It...

Page 9: ...r local territorial authority council you may or may not be able to install a water heating device If in doubt consult your local Metro retailer Water heating is another key feature of your Metro wood...

Page 10: ...the firebox Add dry kindling and move the air control knob fully to the right being the full open position Light the paper at two or three locations across the front of the door opening and leave the...

Page 11: ...moval The time this build up takes depends on the density and cleanliness of your fuel To remove the excess ash your Metro should not be operating Open the door and using a hearth shovel or similar em...

Page 12: ...but its starting too and is getting worse The pipe is in need of a clean It is recommended that the flue pipe to be cleaned every season however if you are burning the fire on low a lot or are using...

Page 13: ...een neglected by not being regularly maintained and serviced warranty may be declined It is critical that the fire not be operated with over worn faulty or missing door seals Door seals will harden ov...

Page 14: ...s renewable fuel is compressed into a dense pellet allowing for maximum heat to be released Check out Metro s new flame today Metro Solar Systems Metro Solar brings together Pioneer Manufacturing Ltd...

Page 15: ...od fire keeping it in good order for many years to come Pioneer heating accessories ECO Flue Systems Pioneer Flashrites Pioneer Versatiles Lead Aluminium Silicone Pioneer Fire Cement Pioneer Fireguard...

Page 16: ......

Reviews: