PacketLINK User Manual
20
4-4 Configuration
1. Connect the PC or laptop COM port to the PacketLINK console port
2. Open Terminal (115200, 8, N, 1) and login in to the PacketLINK unit.
Password:
admin
, logs you in as a basic user
CLI>
passwd
Enter Password:
gciadmin
, logs you in as an administrator which is required for most
configuration changes
3. Cut and paste the relevant CO script from Section 5
4. Connect the PC or laptop to the CPE PacketLINK console port and repeat the above process
using the relevant CPE script from Section 5.
4-5 Test
1. Connect the E1 BERT tester to the CO PacketLINK E1 port number 1
2. If PL1100 units then connect the E1 loopback plug into CPE PacketLINK E1 port
3. If PL1400 units then connect the E1 crossover cables from E1 ports 2-3 on the CO unit and
E1 ports 1-2 and 3-4 on the CPE unit. Connect the E1 loopback plug into CO E1 port 4.
4. If PL1820 units then connect the E1 crossover cables from E1 ports 2-3, 4-5, 6-7, 8-9, 10-11,
12-13 and 14-15 on the CO unit and E1 ports 1-2, 3-4, 5-6, 7-8, 9-10, 11-12, 13-14 and 15-16
on the CPE unit. Connect the E1 loopback plug into the CO E1 port 16.
5. Test the pair of PacketLINK units using the E1 BERT tester