QUICK START CONFIGURATION
22
76-02-059A
4 . 11. 2 J1 Path Trace Identifier
In order to identify the VC-3 that is carrying the E3/DS-3 a label may be attached. This is in
the form of a 15 byte user string and an automatically appended CRC7 byte. The user may
configure the following on a per tributary basis:
J1 Transmit : “String of up to 15 alphanumeric characters"
J1 Receive: “String of up to 15 alphanumeric characters"
If an expected J2 receive value is configured, the MetroLAN will declare a TIM alarm when
there is a mismatch between the configured expected and actual receive J2 identifiers.
4.12 Remote Management Configuration
To access the MetroLAN remotely via an Ethernet connection a connection is required to the
Management Port on the rear panel of the MetroLAN. The Management port supports
10BaseT and is presented MDI on RJ45 for direct connection into a switch. The
management port is fixed for operation at 10Mbps, Half Duplex.
4 . 12. 1 Setting the Unit IP Address
From the MAIN SET-UP menu, select the MANAGEMENT menu and then select the
ETHERNET menu.
In order to set, or change, the IP address the LAN port state must first be set to
DOWN
.
Configure the IP address using the format AA.BB.CC.DD
Configure the Network Mask, if not Class C
Activate the LAN port by changing the state to
UP
4 . 12. 2 Setting a default Route
From the MAIN SET-UP menu, select the MANAGEMENT menu and then the IP menu, and
then select the ROUTING TABLE. To add a new entry as the default route proceed as
follows:
Destination 0.0.0.0
Mask 0.0.0.0
Interface Select Ethernet interface
Next Hop IP Address of Next Hop Router