Metrix PX 110 Manual Download Page 7

24

Wattmeters

1.4

Repair and metrological verification

Information and address details available on request:
Tel. (33) (0)2.31.64.51.55 - Fax (33) (0)2.31.64.51.72

1.5

Unpacking - Repacking

All the equipment was checked mechanically and electronically before shipment.
Every precaution was taken to ensure that you receive the instrument undamaged.

It is a good idea however to check quickly to detect any damage that may have occurred
during transport.

If there is any damage, immediately notify the transporter of the customary reservations.

Caution!

If you ship this instrument on elsewhere, use preferably the original
packaging and indicate the reasons for reshipment as clearly as possible
in a note enclosed with the equipment.

Note:

Our products are patented in FRANCE and ABROAD. Our logos are
registered trade marks.
We reserve the right to modify the characteristics and prices should
technological advances make it necessary.

2.

DESCRIPTION OF THE INSTRUMENT

The PX 110 and PX 120 wattmeters 

can be used to measure AC and DC power levels,

voltages and currents. They have been designed specifically for general and technical colleges,
installers and maintenance departments.

The PX 110 is a single-phase only wattmeter, while the PX 120 provides the possibility of
measuring three-phase power levels, but only three-phase with 3 balanced wires (T3FE);
both models enable measurement in all four quadrants.

These wattmeters give priority to reliability, robustness, safety, simplicity of use and rapidity
of implementation (automatic range change).

The two models have a two-way communication interface (optical head).

The two models measure:
- AC voltages from 500 mV to 600 V rms,
- DC voltages from 500 mV to 600 V,
- AC currents from 10 mA to 10 A,
- DC currents from 10 mA to 10 A,
- DC power levels up to 6 kW,
- AC active power levels up to 6 kW,
- AC reactive power levels up to 6 kVAR,
- AC apparent power levels up to 6 kVA
- the power factor.

The measurement range concerning the fundamental frequency is 40 to 70 Hz.

The bandwidth is 1 kHz (harmonics).

The AC and DC components are not dissociable (RMS values).

Chapter II

北京海洋兴业科技股份有限公司(证券代码:839145)

电话:010-62176775

Summary of Contents for PX 110

Page 1: ...PX 110 PX 120 839145 010 62176775...

Page 2: ...LD SMOOTH INRUSH PF kW kVAR kVA O PX 110 POWER METER ON OFF DISPLAY INRUSH SMOOTH HOLD Se reporter au 2 Description See 2 Description Siehe 2 Beschreibung Vedi 2 Descrizione Remitirse al 2 Descripci n...

Page 3: ...rter au 2 Description See 2 Description Siehe 2 Beschreibung Vedi 2 Descrizione Remitirse al 2 Descripci n HOLD T3FE SMOOTH INRUSH PF kW kVAR kVA O PX 120 POWER METER T3FE ON OFF DISPLAY INRUSH SMOOTH...

Page 4: ...RACTERISTICS 26 3 1 Reference conditions 26 3 2 Voltage measurements V 27 3 3 Current measurements A 27 3 4 Power measurements 28 3 5 Communication option 32 3 6 Mains power supply option 32 4 GENERAL...

Page 5: ...nd portable tool power supplies CAT III CAT III circuits are high power appliance power circuits which may carry high level transient over voltages Example industrial machinery or instrument power sup...

Page 6: ...anyone to use it until it has been checked It is advisable to remove the batteries if the instrument is not going to be used for a long time 1 2 Protective systems This instrument is equipped with sys...

Page 7: ...T The PX 110 and PX 120 wattmeters can be used to measure AC and DC power levels voltages and currents They have been designed specifically for general and technical colleges installers and maintenanc...

Page 8: ...bling the instrument to be set up in a tilted position The mains power supply option which is connected in place of the battery hatch 2 2 Display The liquid crystal display allows the display of numer...

Page 9: ...on components by current overload The field of application is limited to industrial frequencies 40 Hz 70 Hz 3 IMPLEMENTATION FUNCTIONAL CHARACTERISTICS The instrument is activated and shut down by pre...

Page 10: ...2 counts Accuracy for DC 1 of reading 3 counts Resolution 0 1 V Display stability 5 cts in normal mode 2 cts in SMOOTH mode Repeatability of the measurement 0 2 typical Display response time 500 ms i...

Page 11: ...SMOOTH mode 5 cts in normal mode 2 cts in SMOOTH mode Response time 500 ms in normal mode of the digital display 3 s in SMOOTH mode 1 Above 10 A 3 the display indicates OL 3 3 3 Characteristics in INR...

Page 12: ...right complying with the polarities indicated red lead on the terminal and black lead on the COM terminal Set up as indicated in the connection diagrams in Fig 4 4 1 single phase or Fig 4 4 2 balanced...

Page 13: ...VA Characteristics Display range 1000 VA 6 kVA Measuring range 10 0 VA 999 9 VA 1000 VA 5999 kVA Accuracy at 50 Hz 1 5 of reading 2 cts 1 of reading 2 cts Resolution 0 1 VA 1 VA 3 4 4 Reactive power...

Page 14: ...e polarities indicated red lead on the terminal and black lead on the COM terminal Connect the measurement leads to the instrument s voltage measurement terminals on the right complying with the polar...

Page 15: ...d with a mains power supply adapter EN 61010 1 600V Cat III 6 9 VA as an option The battery hatch can be removed and replaced with an adapter connected to the AC mains network Connection The adapter h...

Page 16: ...326 1 Electrostatic discharge IEC 61000 4 2 4 kV contact 8 kV air aptitude criterion A industrial site Electromagnetic field IEC 61000 4 3 10 V m aptitude criterion A industrial site Bursts IEC 61000...

Page 17: ...wer 0 7 Current 0 04 Battery voltage 6 5 to 10 V Voltage 0 04 Power 0 1 Common mode Current 0 2 for U 230V 50 Hz Note The term Power covers the active power P and its associated values Q S and PF 5 AC...

Page 18: ...ine batteries taking care to comply with the polarities indicated on the printed circuit Reinstall the hatch and lock the quarter turn screw 6 2 Replacing the fuse Disconnect the leads from the instru...

Reviews: