background image

A 1513 Discharge Link                                                              

Technical specifications

 

 

5  Technical specifications 

 

Discharge resistors: 

Discharging rate for capacitive load .............. < 0.6 s / µF at 10 kV 
Discharging resistance .................................. 100 k

 

 15 % 

 

Max discharging capacitance ........................ 10 

μ

F at 10 kV 

Max discharging current ............................... 100 mA at 10 kV 
Max discharging voltage ............................... 10 kV 
Intermitent operation ................................... 1:50 

 

Dimensions:

 

Case  ............................................................. ABS 
Dimensions (W x H x L) ................................. 200 mm x 120 mm x 90 mm 
Weight .......................................................... 1.44 kg 

 
 

Protection classification ................................ reinforced insulation  

 

Over-voltage category .................................. 0, no overvoltages 
Pollution degree ........................................... 2 
Degree of protection .................................... IP 54 

 

Reference conditions: 

Reference temperature range ...................... 25 

C ± 5 

Reference humidity range ............................ 40 %RH 

 60 %RH 

 

Operation conditions: 

Working temperature range ......................... -10 °C 

 50 °C  

Maximum relative humidity.......................... 90 %RH (0 °C 

 40 °C), non-condensing 

Working nominal altitude ............................. up to 2000 m 

 

Storage conditions: 

Temperature range ....................................... -10 °C 

 +70 °C 

Maximum relative humidity.......................... 90 %RH (-10 

 +40 

C) 

 ...................................................................... 80 %RH (40 

 60 

C) 

 

Summary of Contents for A 1513

Page 1: ...METREL test and measurement accessories Discharge Link Adapter A 1513 Instruction manual Version 1 1 1 Code no 20 752 541...

Page 2: ...rel si e mail metrel metrel si Mark on your equipment certifies that this equipment meets the requirements of the all applicable EU European Union regulations 2016 METREL No part of this publication m...

Page 3: ...ND OPERATIONAL CONSIDERATIONS 2 2 1 WARNINGS AND NOTE 2 2 2 MARKINGS ON THE A 1513 3 2 3 STANDARD APPLIED 3 3 WORKING WITH A 1513 4 3 1 DESCRIPTION 4 3 2 A 1513 OPERATION 4 3 3 EXAMPLE OF DISCHARGING...

Page 4: ...is unit contains a high ohm discharge resistor 10 kV enclosed in double insulation plastic package A 1513 Discharge Link is special accessory intended for use only with METREL Insulation testers like...

Page 5: ...part of Insulation measurement with Metrel instruments Do not use the A 1513 for primary discharge discharge of tested objects before measurements Never use the A 1513 with voltages higher than rated...

Page 6: ...rd applied The A 1513 Discharge Link Adapter is manufactured and tested according to the following standard listed below Safety LVD EN 61010 1 Safety requirements for electrical equipment for measurem...

Page 7: ...ration To use the A 1513 Discharge link follow these instructions Manual discharge of capacitive load Guarde HV cabel A 1513 Figure 3 2 Manual discharge example Step 1 After the Insulation measurement...

Page 8: ...R s t DUT U 0 0 0 DUT Charged to At time t the voltage on DUT is Voltage U0 Capacity C0 t 0 2 s t 0 5 s t 1 0 s t 2 0 s t 5 0 s Example 1 10 kV 1 F 1 3 kV 67 3 V 0 45 V 0 0 V 0 0 V Example 2 5 kV 10...

Page 9: ...ecial maintenance is required for the housing To clean the surface of the A 1513 Discharge Link adapter use a soft cloth slightly moistened with soapy water or alcohol Then leave the A 1513 to dry tot...

Page 10: ...mensions W x H x L 200 mm x 120 mm x 90 mm Weight 1 44 kg Protection classification reinforced insulation Over voltage category 0 no overvoltages Pollution degree 2 Degree of protection IP 54 Referenc...