METREL A 1398 PQA Instruction Manual Download Page 2

 

 
Distributor: 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Manufacturer: 
 
METREL d.d. 
Ljubljanska cesta 77 
1354 Horjul 
Slovenia 
web site: 

http://www.metrel.si

 

e-mail: 

[email protected]

 

 
 

 

Mark on your equipment certifies that it meets requirements of all subjected EU regulations

 

 

 

Hereby, Metrel d.d. declares that the A 1398 PQA is in compliance with subjected 
EU directives. The full text of the EU declaration of conformity is available at the 
following internet address 

https://www.metrel.si/DoC

. 

 
 

© 2021 METREL 

 
 

The trade names Metrel

®

, Smartec

®

, Eurotest

®

, Auto Sequence

®

 are trademarks registered in Europe and 

other countries. 

No  part  of  this  publication  may be  reproduced  or  utilized  in  any  form  or by  any means  without 
permission in writing from METREL. 

Summary of Contents for A 1398 PQA

Page 1: ...Iron Current Clamp A 1398 PQA Instruction manual Version 1 1 1 Code No 20 753 248 ...

Page 2: ...eclares that the A 1398 PQA is in compliance with subjected EU directives The full text of the EU declaration of conformity is available at the following internet address https www metrel si DoC 2021 METREL The trade names Metrel Smartec Eurotest Auto Sequence are trademarks registered in Europe and other countries No part of this publication may be reproduced or utilized in any form or by any mea...

Page 3: ...e of contents 1 General Description 4 Typical applications 4 2 Safety and operational considerations 5 Warnings and notes 5 Standards applied 6 3 Current clamp operation 7 4 Inspection 8 5 Cleaning 8 6 Service and Calibration 8 7 Technical specifications 9 ...

Page 4: ...mps Typical applications Power Quality Measurement The A 1398 PQA current clamps have linear response through wide frequency bandwidth Therefore they are well suited for Power Quality auditing EN 50160 or troubleshooting Particularly for o Current distortion measurement o Inrush measurement o Functional testing of appliances machines etc High precision and measurement range up to 20A can cover mos...

Page 5: ...Before each use inspect the A 1398 PQA Iron Current Clamp and its latching system for any damage Pay particular attention to the insulation surrounding the jaw Look for cracks or missing portions of the clamp housing or output cable insulation Also look for loose or weakened components Don t use current sensor if the wear indicator of the cable connection is visible Do not use a clamp that is crac...

Page 6: ...ical equipment for measurement control and laboratory use EMC requirements Part 2 2 Particular requirements Test configurations operational conditions and performance criteria for portable test measuring and monitoring equipment used in low voltage distribution systems Safety LVD EN 61010 1 Safety requirements for electrical equipment for measurement control and laboratory use Part 1 General requi...

Page 7: ...ed Make sure that probe jaws are tightly closed around the conductor s In the case of measuring current near live naked conductor s remove electrical power from wires before clamping follow the requirements of EN 50191 Figure 2 Current clamps A 1398 PQA connection to the measuring instrument Step 3 Select Phase and Neutral clamps to Smart Clamp in Connection setup menu on your instrument Step 4 Ob...

Page 8: ...a soft cloth slightly moistened with soapy water or alcohol Then leave the A 1398 PQA to dry totally before use Warnings Do not use liquids based on petrol or hydrocarbons Do not spill cleaning liquid over the A 1398 PQA 6 Service and Calibration It is essential that your clamp is regularly calibrated in order to guarantee the technical specification listed in this Instruction manual We recommend ...

Page 9: ...imensions W x H x L 27 mm x 52 mm x 170 mm Weight 340 g Safety specification Over voltage category No CAT can be used on insulated conductors in 300 V CAT II Pollution degree 2 Degree of protection IP 40 EMC Emission Class B Immunity Portable equipment Environment conditions Working temperature range 10 C 50 C Storage temperature range 20 C 60 C Humidity range 0 RH 80 RH Reference temperature rang...

Reviews: