background image

Figure 1

 

SPECIFICATIONS 

 
2-1 General Specifications 

Position Error 

+/- 1% of Reading.

 

Type Of Sensing 

Hall effect sensing for AC and DC.

 

Low Battery Indicator 

Red LED indicator.

 

Power On Indicator 

Green LED indicator , flashing.

 

Temperature Coefficient 

0.2 x (Spec.Acc’y) / °C , < 18°C    or > 28°C .

 

Power Requirement 

Single 9V battery (NEDA 1604A or IEC 6LF22) (Use supplied)

 

Battery Life 

66 hours typical (Alkaline). 

 

Max / Conductor Size 

22mm diameter. 

Size 

66mm (W) x 185mm (L) x 40mm (H) 

Weight 

270 grams 

Accessories 

Coiled cable output plugs (installed) , manual and carrying case. 

 

2-2 Environmental Conditions 

Indoor use 

 

Maximum Altitude                     

  2000 Meter 

Measurement Category 

 

    IEC 61010-1 600V CAT. III. 

Pollution Degree                        

   

Operating Ambient                   

    0ºC ~ 50ºC , <75%R.H. 

Storage Temperature     

    

-20ºC ~  60ºC,  < 80% R.H.

 

 

2-3  Electrical Specifications 

 
All at 23ºC ± 5ºC, less than 75% R.H. 

 

Ranges                         

0 ~ 40A / 300A AC 

                  

0 ~ 40A / 300A DC 

(1) DC Current   

 

 

 

Ranges                           

40A, 300A 

 Output 

Voltage 

 

10mV / A for 40A Range 

                  

1mV / A for 300A Range 

 

Accuracy           

 40A 

Range 

 

(0 - 40)A   

±

(1.0% + 0.2A) 

                  

300A Range    (40 - 200)A 

±

  (1.0% + 1A) 

Reviews: