background image

 

 

Page 3 

 

 

 

 

Tripod Turnstile Technical Manual 

Tripod Turnstile 

Technical Manual

 

 
Manufacturer: 

Metra inženiring d.o.o. 
IOC Trzin  
Špruha 19 
SI-1236 Trzin, Slovenia 

phone: 
fax: 
web: 

+386 1 56 10 740 
+386 1 56 10 744 

www.metra.si

 

 

 

 

System: 

Metra Access Control 

Product Group: 

Tripod Turnstile 

Types: 

 

TTIS(CC) 

(ISO Reader)

 

 

TTISIS(CC) 

(ISO Reader on both sides)

 

 

TTRIS(CC) 

(ISO Wristband Capturer)

 

 

TTRISIS(CC) 

(ISO Wristband Capturer and Reader)

 

 

TTRCIS(CC) 

(ISO Card Capturer)

 

 

TTRCISIS(CC) 

(ISO Card Capturer and Reader)

 

 

 

TTMF(CC) 

(Mifare Reader)

 

 

TTMFMF(CC) 

(Mifare Reader on both sides)

 

 

TTRMF(CC) 

(Mifare Wristband Capturer)

 

 

TTRMFMF(CC) 

(Mifare Wristband Capturer and Reader)

 

 

TTRCMF(CC) 

(Mifare Card Capturer)

 

 

TTRCMFMF(CC) 

(Mifare Card Capturer and Reader)

 

 

Year of Construction: 

1995 - 2011 

 

 

Declaration of Conformity: 

 

The Metra Access Control products have been developed, designed and 
manufactured in accordance with the EU directive for 

Electromagnetic Compatibility (2004/108/EC)

 

 

 

Tripod Turnstile Technical Manual 

[rev.1-240812]

 

2012 Metra inženiring d.o.o. 

All Rights reserved. 

No part of this manual may be reproduced in any form or by any means without prior written permission of Metra inženiring d.o.o. 
The contents of this manual are subject to change without notice. All efforts have been made to ensure the accuracy of  the contents of this manual,  however, should any errors be 
detected, Metra inženiring would greatly appreciate being informed of them.  
Metra inženiring d.o.o. can assume no responsibility for any errors in this manual. 

 
 
 

 

Product description 

 

 
 
 

 

Tripod Turnstile is a complete, compact access control 
point.  It  combines  motorized  rotating  barrier  with 
RFID  readers  to  control  entrance  and  exit.  Because 
everything  is  integrated  into  a  single  housing,  it 
reduces required space for passage.  
For exit control a patented Metra 

Wristband Capturer 

can  be  integrated  to  allow  Ticket  retain  feature.  The 
storage drawer for captured wristbands and/or cards 
is incorporated in the housing that is a combination of 
stainless  steel  body  in  matte  finish  and  synthetic  or 
carbon fibre reinforced resin cover. Fluent pedestrian 
passage is achieved by combination of visual LED and 
audio  signalization  and  proximity  sensors  triggering 
motor driven rotating barrier. The drive was designed 
and proven to prevent any injury but is tough enough 
to  withstand  misuse  at  the  same  time.  The  barriers 
are free rotating if the mains power is down and can 
also  be  equipped  with  a  special  breaking  fuse 
(mechanical) for the case of panic. 

Summary of Contents for Tripod

Page 1: ...Tripod Turnstile Technical Manual ...

Page 2: ...lation 6 Wires installation 8 Anchor position orientation 8 Preparation of wiring 8 Wiring 8 Anchor installation 9 Other installation options 11 Opening cover 11 Connections 12 Top 12 Bottom 13 Power supply connection 14 Network connection 15 DIP switch settings 16 Operating mode and Network address 17 Power ON 17 Spare Fuse 18 Safety features 19 Free passage 19 Special braking fuses optional 19 B...

Page 3: ...inženiring d o o The contents of this manual are subject to change without notice All efforts have been made to ensure the accuracy of the contents of this manual however should any errors be detected Metra inženiring would greatly appreciate being informed of them Metra inženiring d o o can assume no responsibility for any errors in this manual Product description Tripod Turnstile is a complete c...

Page 4: ...ive feature Metra has developed patented in 1998 contact less Wristband Capturer WBC together with contactless RFID Wristband The Wristband Capturer grants exit signal only when the ticket is successfully erased and retained This dramatically cuts costs of the system operation and the chance of fraud A ticket will be retained under following conditions Retain request written on it assigned to it I...

Page 5: ...omponents inside the Tripod Turnstile Those are Master PCB Slave PCB Turnstile Drive Mechanism II Mechanism and Motor Driver PCB and Wristband Capturer optional Consult the Turnstile Drive Mechanism II Technical Manual and Wristband Capturer Technical Manual for more details about those two components description description 1 Buckle 4 Connection board 2 Turnstile Drive Mechanism II 5 Slave electr...

Page 6: ...ing the orientation and location of Tripod Turnstile s Receptionist should have good overview to the front side of the device s The best position regarding reception desk is that receptionist has access to incoming and leaving guests extra payment on leaving When an entrance for disabled persons is mounted it needs to be at least 90 centimetres wide If the device stands alone you need to mount a b...

Page 7: ...rotected from direct sun and rain The best place for this purpose is inside the building or under projecting roof At night or when device is out of stuff control it is better to have some kind of protection against vandalism wire fence door etc When the device is installed directly on concrete foundation durable carpet should be provided Fixing the Turnstile is done in two levels which also enable...

Page 8: ...ce of the built in anchors Preparation of wiring Put a ribbed plastic hose 30 millimetres for installation of cables through the anchor on the entrance side If installation requires for example external Enter Exit buttons are on different location than Power supply and Metra Net Network more than one ribbed plastic hose can be put in Each installed cable should be at least 1 5 metre long from the ...

Page 9: ...k Mandatory Twisted pair or UTP cable 2 8 if UTP 3 External ENTER EXIT Buttons Optional 0 75 mm soft wire PPL 4 Anchor installation See chapter Mounting set optional for required mounting elements STEP 1 Fix iron anchor spacers to the anchors with supplied M8 nuts STEP 2 Cut sides of the anchor s top view should be placed at the Turnstile s passage side ...

Page 10: ... level as ceramics marble final foundation etc When the concrete is dry the anchor spacers are removed and can be used again STEP 4 Attach the Tripod Turnstile on the anchors and fix it with 6 x M8 nuts Use M8 washers with external diameter at least 24 millimetres or bigger Washers are not included with the anchors and must be bought separately or they are provided by Metra when installing the Tri...

Page 11: ...en depending on the pave type NOTE Drilling holes in pavement is not advised in the following cases Non solid pavement Floor heating Other floor installations NOTE Wiring scheme remains the same for all kinds of installations Opening cover STEP 1 Unlock and remove the ticket container on one side and the door on the other side of the Tripod Turnstile STEP 2 There is a buckle holding the Cover in p...

Page 12: ...ption description 1 Semaphore Slave 8 Not Used 2 Semaphore Master 9 Power Metra NET Network 3 Wristband Capturer 10 Antenna Signalization LED 4 Reader Master optional 11 Metra NET Network 5 Reader Slave optional 12 Metra NET Network 6 Not Used 13 Not Used 7 Not Used ...

Page 13: ...n input Master 9 Not Used 2 Turnstile Drive Mechanism II communication connection 10 Not Used 3 Turnstile Drive Mechanism II power connection 11 Not Used 4 Not Used 12 Not Used 5 Pushbutton input Slave 13 Not Used 6 Not Used 14 BDM Loader 7 Not Used 15 Not Used 8 BDM Loader 16 Not Used ...

Page 14: ...tion of this document for current consumption Connect 24V DC regulated power supply to designated terminals The terminals are marked as 24 for positive connection and gnd for ground connection WARNING Mind the polarity Wrong polarity could result in irreparable damage to the device Respect power requirements data Using unsuitable power supply could result in damage to the power supply and to the d...

Page 15: ...or network low signal and C_H for network high signal OPTION II Connect the twisted pair network cable with RJ 45 connector to one of RJ 45 connectors on the connection board NOTE FOR OPTION II There are 2 equivalent UTP connectors for Metra NET Network connection One can be used as trunk line IN and the other as trunk line OUT connector Take into consideration that if you disconnect one of the UT...

Page 16: ...l flat headed screwdriver or similar object to push DIP switch pins to desired position After each settings change or after device s first installation power off and back on the device for the new settings to take effect and obtain operating parameters if the device is connected to Metra NET Network controlled by Metra Network Controller and Metra SW Operating parameters are obtained through the M...

Page 17: ...gh 8 to indicated positions where 0 indicates the corresponding switch is in OFF position switch down 1 indicates the corresponding switch is in ON position switch up Coding table switch positions Master address Slave address switch positions Master address Slave address 4 5 6 7 8 4 5 6 7 8 0 0 0 0 0 300 332 1 0 0 0 0 316 348 0 0 0 0 1 301 333 1 0 0 0 1 317 349 0 0 0 1 0 302 334 1 0 0 1 0 318 350 ...

Page 18: ... Turnstile Technical Manual description 1 F3 15 A 5mm x 20mm fast fuse 2 Power ON OFF button Spare Fuse Tripod Turnstile uses one F3 15 A 5mm x 20mm fast fuse Spare one is located on the back of the connection board ...

Page 19: ...r safety is required barriers can be equipped with special braking fuses that brake if high force is applied to the barriers people leaning on the barrier mass of peoples push against the barrier Barrier can be easily and quickly reinstalled using a new braking fuse Barrier calibration Each barrier when in top position should be perpendicular to the metal housing Consult Turnstile Drive Mechanism ...

Page 20: ...ts suitable for rust resistant metals The resin cover should be cleaned using soft cloth and dedicated cleaners for plastic surfaces e g car dashboard cleaning agents Do not use any aggressive or abrasive agents or solvents as they might cause permanent damage to the device surface Technical data Operating voltage 24V DC regulated 22 30V DC tolerated Current consumption 2 A Fuse Fast Fuse 3 15 A O...

Page 21: ... Concreting Composition 5 Concrete Installation with Anchors Concrete Installation with Anchor screws 6 Inner connections 7 Configuration Wristband Capturer and Reader 8 Configuration Wristband Capturer 9 Configuration Reader on both sides 10 Configuration Reader ...

Page 22: ...Appendix 1 Tripod Turnstile Physical dimensions 205 795 205 SIDE VIEW FRONT VIEW BOTTOM VIEW 470 270 1220 1020 100 100 270 980 785 TOP VIEW ...

Page 23: ...EXIT RECEPTION DESK PASSAGE FOR DISABLED PERSONS CABLING ELECTRIC LOCK Installation Pipe PVC 30 mm 780 780 Appendix 2 Tripod Turnstile Typical Installation to Server Room ENTRANCE ...

Page 24: ...NSTALLATION MATERIAL IRON PLATE 5mm SURFACE FINISH BLACK POWDER COATING Appendix 3 Tripod Turnstile Build in Anchors HOLE FOR WIRING SCREW M8 SCREW M8 SCREW M8 ANCHOR ANCHOR ANCHOR 30 70 70 30 30 70 80 55 30 265 200 115 Ø 6 0 5 min 12 5 max 150 ...

Page 25: ...Appendix 4 Tripod Turnstile Concreting Composition 100 170 30 1100 1030 1170 1200 30 140 30 ...

Page 26: ...C 30 mm Final fundation Concrete Anchor Installation Pipe PVC 30 mm Final fundation Anchor screws Anchor screws Anchor Concrete Installation with Anchors Appendix 5 Tripod Turnstile Concrete Installation with Anchor screws ...

Page 27: ...endix 6 Tripod Turnstile L O C A L C A N L O C A L C A N R E A D E R S L A V E READER M ASTER S I G N A L I Z A T I O N SIGNALIZATION SLAVE ENTER Pushbutton OPTIONAL EXIT Pushbutton OPTIONAL MASTER Comunnication and power for the Turnstile Drive Mechanism ...

Page 28: ...ration Wristband Capturer and Reader Mounting plate top side SIGNALIZATION READER SLAVE SEMAPHORE MASTER SEMAPHORE SLAVE WRISTBAND CAPTURER 24 GND C_H C_L W B C 24 GND C_H C_L Metra NET Network OPTION A 24V DC Metra NET Network OPTION B ...

Page 29: ...d Turnstile Configuration Wristband Capturer Mounting plate top side SEMAPHORE MASTER SEMAPHORE SLAVE WRISTBAND CAPTURER 24 GND C_H C_L W B C 24 GND C_H C_L Metra NET Network OPTION A 24V DC Metra NET Network OPTION B ...

Page 30: ...ile Configuration Reader on both sides Mounting plate top side SIGNALIZATION SEMAPHORE MASTER SEMAPHORE SLAVE 24 GND C_H C_L Metra NET Network OPTION A 24V DC Metra NET Network OPTION B READER SLAVE SIGNALIZATION READER MASTER ...

Page 31: ...ndix 10 Tripod Turnstile Configuration Reader Mounting plate top side SIGNALIZATION SEMAPHORE MASTER SEMAPHORE SLAVE 24 GND C_H C_L Metra NET Network OPTION A 24V DC Metra NET Network OPTION B READER MASTER ...

Reviews: