Door Access Terminal Combo Technical Manual 

Door Access Terminal Combo 

Technical Manual

 

 
Manufacturer: 

Metra inženiring d.o.o. 
IOC Trzin  
Špruha 19 
SI-1236 Trzin, Slovenia 

phone: 
fax: 
web: 

+386 1 56 10 740 
+386 1 56 10 744 
www.metra.si 

 

 

 

System: 

Metra Access Control System 

Product Group: 

Door Access Terminal Combo 

Types: 

 

DLCIS 

(ISO14443A/B, ISO 15693) 

 

DLCLF

 (LF Multitag) 

 

DLCMF

 (Mifare, ISO14443A/B) 

 

Year of Construction: 

2011 - 2012 

 

 

Declaration of Conformity: 

 

Metra  Access  Control  products  have  been  developed,  designed  and 
manufactured  in  accordance  with  the  EU  directive  for 

Electromagnetic 

Compatibility (2004/108/EC)

.  

 

 

 

Door Access Terminal Combo Technical Manual 

[rev.0-050912]

 

2012 Metra inženiring d.o.o. 

All Rights reserved. 

No part of this manual may be reproduced in any form or by any means without prior written permission of Metra inženiring d.o.o. 
The contents of this manual are subject to change without notice. 
All efforts have been made to ensure the accuracy of the contents of this manual, however, should any errors be detected, Metra inženiring would greatly appreciate being informed of 
them. Metra inženiring d.o.o. can assume no responsibility for any errors in this manual. 

 
 
 

 

Product description 

 

 

Door  Access  Terminal  Combo  (DAT  Combo)  is  designed  to 
form  a  one-way  check  point  in  Metra  Access  Control 
Systems and Electronic Locking Systems.  
In  Access  Control  Systems  a  RFID  media  is  used  as  a  door 
key.  For  higher  security  (e.g.  outside  door,  etc.)  a  user 
specific PIN code as an addition to RFID media can be used. 
In  Electronic  locking  systems  a  RFID  media  or  a  locker 
number  followed  by  a  locker’s  PIN  code  can  be  used  as  a 
door key. 
When access is granted device gives a single relay signal for 
access  mechanisms  such  as  electric  door  strike,  automatic 
door, etc. Normally it is mounted near door where passage 
control is needed. 
Door Access Terminal operates on line with Metra software. 
It must be connected to Metra NET Network. 
Passage on Door Access Terminal Combo for particular RFID 
ticket can also be externally controlled by 3rd party SW via 
TCP/IP software interface. 
Operating  parameters  are  defined  in  the  Metra  software. 
Event data from device is used for further analyses with this 
software. 

 

Summary of Contents for Door Access Terminal Combo

Page 1: ...Door Access Terminal Combo Technical Manual ...

Page 2: ...terface 5 Control module 6 Connections 8 User interface 8 Control module 8 Power supply connection 9 User interface connection 10 Electronic door lock connection 10 Tamper sensor connection 11 Push button connection 11 DIP switch settings 12 Network address 12 Operating indicator 14 Signalization lights 15 Operating parameters 15 Setting Operational parameters via Metra NET Network 16 Setting Oper...

Page 3: ...should any errors be detected Metra inženiring would greatly appreciate being informed of them Metra inženiring d o o can assume no responsibility for any errors in this manual Product description Door Access Terminal Combo DAT Combo is designed to form a one way check point in Metra Access Control Systems and Electronic Locking Systems In Access Control Systems a RFID media is used as a door key ...

Page 4: ...cal Manual Basic Parts Door Access Terminal Combo user interface Door Access Terminal Combo control module 6 pole connection cable 6 pole round to flat cable used to connect Door Access Terminal user interface to the control module Length 3 m ...

Page 5: ... be mounted over an electrical box or directly to the wall See appendices for exact dimensions and mounting holes positions for the user interface STEP 2 Thread the connection wire to the installation point STEP 3 With at least 4 screws attach the metal wall mount to the wall NOTE Screws are not supplied ...

Page 6: ...ch the user interface to the metal wall mount and with 2mm hex screwdriver inbus key lock it in place Rotate the screws counter clockwise NOTE Remove the protective film from the foil Control module STEP 1 Control module can be mounted over an electrical box or directly to the wall See appendices for exact dimensions and mounting holes positions for the control module ...

Page 7: ...ET Network power connection cable for user interface and electronic door lock STEP 3 Attach the control module to the surface If mounted over an electrical box use the hole on the side to wire cables thru it STEP 4 Connect the cables to the control module For details see next chapter Attach the front with 4 supplied screws STEP 5 With two supplied screws attach the front cover ...

Page 8: ...ge 8 Door Access Terminal Combo Technical Manual Connections User interface description 1 User interface control module communication Control module description description 1 Metra NET Network 8 Not Used ...

Page 9: ... irreparable damage to the device Respect power requirements data Using unsuitable power supply could result in damage to the power supply and to the device Metra NET Network connection The Metra NET Network connection provides for operational functionality of the Door Access Terminal Combo Different devices in parallel can be connected to the Metra Network Controller by a single unshielded twiste...

Page 10: ...according your electronic door lock Connect the electronic door lock to the terminals marked RELE on the control module WARNING Mind the power polarity if one of the options with DC output is selected see corresponding schematics Wrong polarity could result in irreparable damage to the device WARNING Mind the electronic door lock power consumption 12 V DC door lock with max 0 5 A current consumpti...

Page 11: ...cal Manual Tamper sensor connection Connect the tamper switch cable to the terminals marked TAMP on the control module Push button connection Connect the cable from normally open Push button to the terminals marked TIPKA on the control module ...

Page 12: ...push DIP switch pins to desired position After each settings DIP switch position change power off and back on the device for the new settings to take effect Network address After installation is complete the device network address must be set by DIP switches NOTE Each Metra device must have different address setting Switch 1 must be set to OFF switch down Look up the code for desired network addre...

Page 13: ... 1 281 0 0 1 0 0 1 0 218 1 0 1 0 0 1 0 282 0 0 1 0 0 1 1 219 1 0 1 0 0 1 1 283 0 0 1 0 1 0 0 220 1 0 1 0 1 0 0 284 0 0 1 0 1 0 1 221 1 0 1 0 1 0 1 285 0 0 1 0 1 1 0 222 1 0 1 0 1 1 0 286 0 0 1 0 1 1 1 223 1 0 1 0 1 1 1 287 0 0 1 1 0 0 0 224 1 0 1 1 0 0 0 288 0 0 1 1 0 0 1 225 1 0 1 1 0 0 1 289 0 0 1 1 0 1 0 226 1 0 1 1 0 1 0 290 0 0 1 1 0 1 1 227 1 0 1 1 0 1 1 291 0 0 1 1 1 0 0 228 1 0 1 1 1 0 0 2...

Page 14: ... 1 319 0 1 1 1 0 0 0 256 1 1 1 1 0 0 0 320 0 1 1 1 0 0 1 257 1 1 1 1 0 0 1 321 0 1 1 1 0 1 0 258 1 1 1 1 0 1 0 322 0 1 1 1 0 1 1 259 1 1 1 1 0 1 1 323 0 1 1 1 1 0 0 260 1 1 1 1 1 0 0 324 0 1 1 1 1 0 1 261 1 1 1 1 1 0 1 325 0 1 1 1 1 1 0 262 1 1 1 1 1 1 0 326 0 1 1 1 1 1 1 263 1 1 1 1 1 1 1 327 Operating indicator When the unit is running a blue OPERATE signal light is flashing Keypad illumination ...

Page 15: ... Power signal 3 OK signal For more about signalization lights see Door Access Terminal Combo User Manual pdf Operating parameters Parameter Value Default Description Signal Time 1 30 6 Signalization duration in seconds Relay Activation Duration 0 30 6 Relay activated for X seconds 0 50ms pulse Relay Activation Latch Unlatch ON OFF OFF Latch Unlatch function ...

Page 16: ...999 OFF OFF Entrance with user card is possible if user card has one or more set lockers assigned to it There are various ways of setting the operating parameters Setting Operational parameters via Metra NET Network Operating parameters are obtained through the Metra NET Network The server must be set up and running for that purpose To obtain operating parameters press the PARAMETERS REQUEST butto...

Page 17: ...vice surface Technical data Operating voltage 12V DC regulated 11 5 15V DC tolerated Current consumption 0 50 A Operating temperature range 10 to 50 C Audio signal integrated piezoelectric beeper Visual signalization 3 LEDs Network type CAN network interface to Network Controller Appendix 1 Physical dimensions User interface 2 Physical dimensions Control module 3 Physical dimensions User interface...

Page 18: ...Appendix 1 Door Access Terminal Combo Physical dimensions User interface 89 147 2 37 1 4 8 10 ...

Page 19: ...Appendix 2 Door Access Terminal Combo Physical dimensions Control module 40 232 105 40 232 105 ...

Page 20: ...Appendix 3 Door Access Terminal Combo Physical dimensions User interface mounting holes 8 60 90 52 60 ...

Page 21: ...Appendix 4 Door Access Terminal Combo Physical dimensions Control module mounting holes 60 30 120 157 36 7 ...

Page 22: ...Appendix 5 Door Access Terminal Inner connections 1 2 5 3 4 6 7 8 ...

Page 23: ...AT5 UTP CAT5 12V DC in 12 V DC must be prepared by a certified electrician 12V DC to other units 2 2 x 0 5 mm Appendix 6 Door Access Terminal Electric installation schematic floor ceiling 120 145 cm ENTRANCE DAT User Interface Gewiss case GW48003 Standard Electric Lock 12V 0 6A Door Sensor optional power requirements 0 5A electric lock consumption for each connected unit ...

Reviews: