background image

12/25      Electric heated Pasta-Cooker (600)

switch.
Sealed components must not be tampered
with.
To reach electrical components, i.e. controls and
safety devices, remove control panel .

Heating elements
– Pull out the control knobs and remove control

panel. Disconnect the faulty heating element
from inside the well and replace it.

Temperature regulation thermostat
– Pull out the control knobs. Remove the front

control panel. Disconnect and replace the faulty
component.

Safety thermostat
– Pull out the control knobs. Remove the front

panel. Remove and disconnect the component to
be changed. Extract the bulb (thermostat) from
the heating element. Change the faulty component.

Water filling and drainage tap
– Pull out the control knobs. Remove the front

panel of appliance, disconnect and replace the
component.

USE AND MAINTENANCE

WARNINGS

Caution , appliance with hot surfaces!
The appliance is for professional use and must be
used by trained personnel.  It is for the  cooking of
food.  Any other use of the appliance is considered
improper.
The installation and adaptation to other voltage
must be done by qualified and authorized installers.
In case of breakdown disconnect the main switch.
Sealed components must not be tampered with.
For repairs consult only authorized service centres
and ask for original spare parts only.
The manufacturer declines any responsability
if such obligations are not observed.
Carefully read this booklet and keep it in a safe place.
Before using the appliance carefully clean all the
surfaces that will come in contact with food.

USE

Filling of well
Close well drain cock, turning control lever to
setting

.

Turn on water feed tap

    and fill the well up to

the indicator notch, turning the control lever to ON.
IMPORTANT  Don’t start heating with an
empty well!

Operation
To switch on heating of well (pilot lamp on) turn
the temperature regulator knob on the desired
working position (ex. Max setting to bring water to

boil).

0

off

Min

minimum temperature

1, 2, 3, 4

intermediate temperatures

Max

maximum temperature (approx.)

Switching off heating
– Turn temperature regulator knob on position 

 

0

(pilot lamp off).

Well drainage
– Open the well drainage tap to position       .

CLEANING

 

AND

 

MAINTENANCE

– Before any cleaning operation disconnect the

electrical supply (if present).

– It is necessary to avoid rusty water being in

contact with stainless steel surfaces. Therefore
before filling wells with water open water tap
and let water flow until it is perfectly clear.

– Clean stainless steel surfaces daily with water

and non abrasive common detergents, rinse
well and dry thoroughly.

– Do not use iron scouring pads or chlorate

products.

– Do not use sharp objects which can scratch and

ruin the steel surface.

– Do not use corrosive products to clean the floor

under the appliance.

– Do not wash the appliance with water jets.
– Before a long period of inactivity disconnect the

main switch. Proceed to its thorough cleaning.

– At least twice a year, ask for the intervention of

an authorized technician authorized for checking
the appliance. It is advisable in any case to
stipulate a maintenance contract.

LIST

 

OF

 

PARTS

 

SUBJECT

 

TO

 

REPLACEMENT

– Temperature regulator
– Knob for temperature regulator
– Safety thermostat
– Heating element
– Pilot lamp
– Water filling tap
– Water drainage tap