Electric heated Pasta-Cooker (600)      11/25

– Connect the metallic structure of every electrical

appliance installed to the terminals, marked by
the symbol

, and located next to the earth

terminals (unipotential system).

Connection to the water piping
– Waterfilling with water tap command on the

front side of the appliance. Water inlet pipe
connection ISO 7/1 R3/8.

The water supply must be fed at a pressure of
between 150 and 250 kPa.

Water draining
– Water drain tap command on the front side of

the appliance. Drain pipe connection: non-
threated Ø 18 mm, sink type siphon joint.

START

-

UP

Function check
– Start-up the appliance following the instructions

given; check function regularity and make sure
that the controls and heating elements are in
good working order, testing them with the
various function positions.

– The appliance has an internal safety thermostat

that switches the heating elements off when the
work thermostat is failing. In case this
thermostat cuts off, remove the screw sealing
the thermostat access hole on the control panel.
Reset the thermostat, pressing with a pointed
tool (e.g. slender screwdriver).

Nominal heat input check
– After installation and at each maintenance

intervention check the heat input of the appliance.

– The nominal heat input is stated in the

“Technical data” table.

– The appliance operates at the nominal heat input

when the electrical power is the one stated in Table T1.

ATTENTION  If  the  power supply value is not
within the limits indicated in Table T1, interrupt
the operation of the appliance and contact the
electricity delivery body.

ANALYSIS

 

OF

 

SEVERAL

 

FAILURES

Heating elements do not heat up
– Check fuse valves
– Main switch off
– Insufficient power or wrong electrical connection
– Regulation thermostat faulty
– Safety thermostat activated or faulty.

Diffcult or lacking temperature adjustment
– Regulation thermostat faulty
– Wrong connection or heating elements faulty

(replace faulty element).

REPLACEMENT

 

OF

 

PARTS

 

SUBJECT

 

TO

 

CHANGE

IMPORTANT   Before carrying out repairs, unplug
appliance from mains disconnecting the main

INSTALLATION INSTRUCTIONS

WARNINGS

Installation, adjustments and maintenance of the
appliances must be done by authorized installers,
in accordance with the safety standards in force.
The manufacturer declines any responsibility
if such obligation is not observed.

INSTALLATION

Positioning
– The overall/connection dimensions and the

technical data are stated in the pages in the
appendix.

– Install the appliances only in sufficiently aired

rooms.

– Position appliances at least 10 cm from the

nearby walls.  Such distance can be less when
the walls are incombustible or protected by a
thermal insulator.

– The appliances are not suitable for built-in

installation.

Assembly
– Remove the film which protects the external

panels. Any glue remaining on these is to be
removed with a suitable solvent.

– Assemble the spacer (if foreseen) by following

the instructions enclosed with the spacer itself.

In line union of the appliances
– Put the appliances next to eachother and level

them at the same height.

– Unite the appliances using the special union

joint-coverings supplied upon request.

Electrical connections
– Appliances are designed to operate at the voltage

indicated on the rating plate.

– Each appliance must be connected to an

independent mains supply of suitable capacity
(total power indicated in “Technical data” table)
via an input terminal board with flexible rubber
cable, insulated at a level not below H07RN-F.

– Make sure that the cables lenght allows for the

live wires to disconnect from terminal block
before the yellow/green ground wire, in case of
simultaneous pull.

– Automatic cutout omnipolar switches of suitable

capacity (with contacts opening to at least 3
mm) and highly sensitive automatic differential
protective devices must be fitted. These must
ensure that there is no direct or indirect contact
between live components and fault currents
and the ground, in accordance with current
regulations (maximum admissible leakage
current 1 mA/kW).

Earth and unipotential connections
– Appliances must be earthed on terminals marked

with the symbol        .