18.9.2007
Rev. 2.4
Installation
10
5.9
Connection to power supply mains
The electrical wiring system scheme is attached inside of the rear panel of the ice flake
maker.
To reach this, unplug the power cable from the socket, loosen the screws, which fasten the
front panel and slide it away.
Electric safety of the automatic ice flake maker is achieved solely when the appliance is
properly connected to an efficient earthing system made in compliance with current na-
tional safety standards. Make sure that this fundamental safety requirement is respected
and, if you are in any doubt, ask for a thorough check of the electric system by profession-
ally qualified and authorized staff. The manufacturer declines all responsibility for dam-
age and/or injury that might ensue from any failure to earth the system properly. It is
essential that the electrical wiring system where the appliance is to be installed should
have adequate current carrying capacity for the maximum power of the appliance, as
shown on the data plate. To achieve a proper and safe installation of the automatic ice
flake maker, it is necessary to provide an appropriate earthed socket, with a contact-open-
ing gap of no less than 3 mm, in accordance with current national safety standards. This
switch must moreover be equipped with fuses (see fig.).
Make sure to unroll the power supply cable to its entire lenght and check that it is not
squeezed in any way.
5.10
Connection to water mains
The automatic ice flake maker is designed solely for producing ice flakes and must be fed
exclusively with cold water for human consumption (drinking water).
The running pressure must be between 0.1 and 0.6 MPa.
Connection to the water mains must be made following the manufacturer’s instructions
by professionally qualified staff.
Between the water mains and the charge pipe of the automatic ice flake maker, a tap must
be installed so that the water supply may be shut off if need be.