07.04.2015
Metos Induction range Ardox IE
11
6. Installation
6.1. General
The installation of this appliance must be carried out in accordance with the manufactur-er’s instructions
and in compliance with local rules and regulations. These instructions must be used together with the
installation drawing of the appliance.
STOP
The connection of the appliance to the electrical and water supply must be carried out by
qualified per-
sons only.
6.2. Ambient conditions
This appliance is intended to be used in the following ambient conditions: Max.ambient temperature:
Storage
-20 C to + 70 C
Function 0 C to+ 40 C
Relative humidity: 10% to 90% non - condensing
6.3. Storage, transporting and unpacking the range
It is recommended to keep appliance in its own package before the actual installation begins. It protects
appliance from outer damages. If it is necessary to unpack appliance, possible lifting must be done from
the bottom frame using suitable spacers of wood.
In order to avoid damages it is not allowed to use ceramic hob surface as a workbenchduring installation.
6.4. Positioning the range
This appliance is equipped with its own internal cooling system. Air inlet is located on the bottom of
stainless steel enclosure (see installation drawing).
Air outlet openings are on the rear side of enclosure.
Temperature of intake air should be below 40°C.
This appliance can not be placed direct near ovens or other heating appliances where ambient tempera-
ture may reach over 40°C.
An optimum air intake must not be reduced by the installation. Pay attention that air ventilation is avai-
lable, see installation drawing min 50 mm from the wall. The grease filter must always be in place when
the range is used.
When the range is in the right place, it must be levelled in horizontal position by turning adjustable legs.
After that, the rear legs must be fixed to the floor by means of flanges and anchor bolts (see installation
drawing).