![Metos 74/02+2CTGG Installation And Operation Manual Download Page 31](http://html1.mh-extra.com/html/metos/74-02-2ctgg/74-02-2ctgg_installation-and-operation-manual_1777983031.webp)
27.2.2004
Rev. 1.0
Installation
23
The appliance should be connected to the gas supply by means of metal pipes --either rigid
or flexible-- having an adequate diameter (see
"Technical specifications table"
at the end
of this manual). When joining pipe fittings, never use oakum or Teflon as their residues
could get to the valve and jeopardise its operation. Instead, interpose a seal gasket suitable
for use in gas systems. Do not forget to fit a shutoff valve on the gas supply line upstream
of the appliance, which should be closed whenever the appliance is not in operation. Op-
erating pressure values are shown on the rating plate and in
"Table 1: gas categories and
pressure values"
above.
After connecting the appliance to the gas system, check for leaks at joints and pipe fit-
tings; to do so, use soapy water or a specific leak detector (spray).
5.11.1 Changing gas inlet connection from the right to the left (optional)
Gas inlet connection may be changed from the right side to the left side using a kit which
includes the following items:
•
1 Male/Female 1/2" elbow;
•
Female/Female 1/2" elbow;
•
Male/Male 1/2" pipe;
•
kit fixing bracket.
To change the gas inlet connection from the right to the left side of the appliance, proceed
as follows:
•
Fix the FF elbow to the gas ramp of the appliance;
•
fix the MF elbow to the MM pipe;
•
insert the pipe into the hole of the fixing bracket and fix it to the FF elbow;
•
screw the bracket to the lower frame;
•
proceed as usual to connect the appliance to the gas supply.
5.12 Checking the supply pressure of the gas after installation
Gas supply pressure may be measured by using a liquid (e.g., a U-tube manometer with
0.1 mbar scale resolution) or a digital manometer.
Summary of Contents for 74/02+2CTGG
Page 2: ......
Page 4: ...27 2 2004 Rev 1 0...
Page 7: ...27 2 2004 Rev 7 Troubleshooting 43 9 Technical specifications 81...
Page 8: ...27 2 2004 Rev...
Page 12: ...27 2 2004 Rev 1 0 Safety 4...
Page 16: ...27 2 2004 Rev 1 0 Functional description 8...
Page 38: ...27 2 2004 Rev 1 0 Installation 30...
Page 50: ...27 2 2004 Rev 1 0 Adjustment instructions 42...
Page 54: ...27 2 2004 Rev 1 0 Troubleshooting 46...
Page 56: ...SC00414 wiring diagram 74 02CTGE 3 N PE 400V 50 60 Hz...
Page 58: ...SC00415 wiring diagram 76 02CTGGE 1 N PE 230V 50 60Hz...
Page 70: ...27 2 2004 Rev 1 0 Technical specifications 96...
Page 72: ...27 2 2004 Rev 1 0 Technical specifications 98...
Page 74: ......
Page 75: ......
Page 76: ......