Metos SW-III
3.5. 3Set limits
• In the weighing mode, press and hold
TARE
key. Display will be show “0.000” ( Hi limits set ) and
Red back light.
• Press
TARE
key to change the value, press
ZERO
key to shift locatio. When the shift to the last, press
ZERO
key to confirm. Display will be show “0.000” ( Low limits set ) and Orange back light .
• Press
TARE
key to change the value, press
ZERO
key to shift locatio. When the shift to the last, press
ZERO
key to confirm and come back to the weighing mode
Back light color
High : Red
Ok : Green
Low : Orange
4. Parameters & Calibration
4.1. Enter setting mode
To set parameters, first turn on the weighing scales, hold the tare key during self-checking, until display
show “F1 CAL”, then need press the calibration switch.
4..2 Calibrate
After enter setting parameter, the display will show ”F1 CAL”. press zero key, display shows “UNLD”,
empty the platter, after STABLE indicator on, press zero key again, display shows the calibrate weight,
you can press tare key to select calibrate weight, after you select, put the calibrate weight on, after STAB-
LE indicator on, press zero key to sure, display shows “pass ”, the calibrate finish .
4.3. Set resolution
After enter setting parameter, the display shows “F1 CAL”, press tare key, display shows “F2 RES ”, press
ZERO key to enter, press tare key to select resolution,
4.4. Change capacity
After enter setting parameter, the display shows “F1 CAL”, press tare key, until display shows “F3 CAP ”,
press ZERO key to enter, press tare key to select capacity , press zero key to sure.
4.5. Check internal counts
After enter setting mode, display shows “F1 CAL”, press tare key select , until display shows “F4 INP”,
press zero key to enter, display shows internal counts, press TARE key to return setting mode.
4.6. Power auto off
After enter setting parameter, the display shows “F1 CAL”, press
TARE
key, until display shows “F5 OFF
”, press
ZERO
key to enter, press
TARE
key to select the auto off time(3/5/15/off) , press
ZERO
key to
confirm.
Note
Below the scale there is a breathable knob. Its default setting is for weigh. If you want to wash tighten
the knob, after wash release the knob for weigh
When want to weigh, release
screw for getting normal
pressure
When want to wash, tight sc-
rew for getting seal