This section describes the specifications, components, and theory of the TEROS 06.
3.1 SpECIFICATIONS
MEASUREMENT SpECIFICATIONS
Temperature
Range
–20 to +50 °C
Resolution
±0.03 °C
Accuracy
±0.1 °C (0 to 30 °C)
±0.2 °C (–20 to 50 °C)
Measurement Depths
5 cm, 10 cm, 20 cm, 30 cm, 50 cm, 100 cm
COMMUNICATION SpECIFICATIONS
Output
SDI-12 one-wire serial interface
• DDI serial communications protocol
• SDI-12 communications protocol
RS-485 two-wire serial interface (M12 connector only)
• tensioLINK serial communications protocol
• Modbus RTU communications protocol
Data Logger Compatibility
METER ZL6 data loggers and any data acquisition system capable of 3.9- to 28.0-VDC
power and serial interface with SDI-12 and/or RS-485 interface, Modbus RTU, or
tensioLINK communication
pHySICAL SpECIFICATIONS
Dimensions
Length
104.0 cm (40.94 in)
Diameter
2.0 cm (0.79 in)
Operating Temperature Range
Minimum
–30 °C
Maximum
60 °C