background image

4

 

 

 

STATUS LEDS 

The meaning of the LEDs on the front of the blue’Log: 

Symbol 

LED 

Meaning 

 

 

Green: 

blue’Log is supplied with power 

 

Off: 

No power supply 

 

 

Green: 

System loaded successfully, normal 

operation 

 

Orange:  

System booting, boot phase 

 

Red: 

System error 

 

 

Green: 

Connected to VCOM 

 

Orange:  

Establishing connection to VCOM 

 

Red:  

No connection to VCOM 

 

BLUE’LOG CONFIGURATION – NETWORK 

The  blue’Log  is  configured  via  your  web  browser  (e.g.  Chrome,  Firefox).  In  order  to 
configure it, you must first configure the network and set up user access. 

Network configuration 

The Ethernet connection of the blue’Log must be connected to a LAN network (e.g. 

LAN interface PC, router, switch) 

The current IP address of the blue’Log is shown on the display’s start screen. 

 

Network: 

 

With DHCP server:  

IP address assigned by DHCP server

 

 

Without DHCP server:  IP address generated randomly by the 

blue’Log 

 

 

 

(range: 169.254.XXX.XXX) 

To adjust your network parameters (DHCP or static), navigate to the network settings 

by using the directional pad and the buttons. 

 

 

Summary of Contents for BLUE LOG XM

Page 1: ...BLUE LOG XM XC Quick Start Guide Version 20180827...

Page 2: ...top hat rail latch 10 Network socket RJ45 11 Interface RS485 1 12 Bus termination of 13 Bus termination of 14 Interface RS485 2 15 Voltage output 24 V 500 mA 16 Power supply 24 V 17 Digital inputs 4x...

Page 3: ...top hat rail Press the device Latch nose extended Closed latch position up WALL INSTALLATION Insert two screws 80 mm apart into the wall Hang the device on the screws using the recesses on the rear s...

Page 4: ...estricted by using an energy limited circuit A DC source with limited power may also be used The power supply of the blue Log must meet the following requirements Device protection Voltage 24 V DC Cur...

Page 5: ...web browser e g Chrome Firefox In order to configure it you must first configure the network and set up user access Network configuration The Ethernet connection of the blue Log must be connected to a...

Page 6: ...ort DNS Netbios http blue xnnnnnnnn No DNS Netbios http blue xnnnnnnnn local n last eight digits of the hardware number The host name can be changed via the web interface in the System Ethernet menu S...

Page 7: ...te the access meteocontrol is not able to connect to the device in case of service You can change the setting at any time in the menu System User Firmware update and time zone When using the device fo...

Page 8: ...ware number HW No the blue Log user name and the password Note regarding data protection GDPR At this point we would like to inform you what data we collect when you configure and use the blue Log Use...

Reviews: