3
3. Unit Identification
Figure 1 HCT-PS1000 Power Supply
Figure 3: Run Mode, Before Profile Start
Figure 4: Run Mode, After Profile Start, MRS Mode
Z 1 :
1 5 0 °c
6 5 s
P 0 6
Z 2 :
2 0 0 °c
5 5 s
T C : I
N T
Z 3 :
2 5 0 °c
4 5 s
Z 4 :
3 0 0 °c
3 0 s
Z 1 :
5 5 s
P 0 6
T - S E T :
1 5 0 °c
T C : I N T
T - H t r :
1 3 6 °c
1 2 5 °c
R E M O V E
(
↵
)
Enter/Profile Select
Power On/Off
Timer/Temperature Adjust Down
⊕
Timer/Temperature Adjust Up
and Profile start/abort
Thermocouple (TC1)
Thermocouple (TC2)
Hand-piece Connector
Power Connector
Footswitch Connector
Communications Connector
Figure 2
Back Panel Detail
T
C
1
:
Active Zone
Zone Set Point
Actual Heater Reading
Temperature Monitor
Thermocouple
Control
Selected Profile
Place/Remove Option
(Only Available in MRS Mode)
Zone Target Temperature
Profile Parameters