![Metasys COMPACT Dynamic Equipment Logbook Assembly, Operation And Maintenance Download Page 13](http://html.mh-extra.com/html/metasys/compact-dynamic/compact-dynamic_equipment-logbook-assembly-operation-and-maintenance_1777411013.webp)
RESET
RESET
RESET
RESET
RESET
RESET
RESET
PUSH 5 sec
RESET
2,5Hz
const.
34
35
36
37
38
39
40
const.
const.
= leuchten
= blinken
= permanent
= flashing
= allumé
= intermittent
= rimane accesa
= lampeggiare
34.1
34.2
13
EN
17. Service mode
The electronic components of the COMPACT Dynamic amalgam separator
allow for the their functions to be checked using a service mode.
IMPORTANT! In order to resume normal operation or service
mode after the equipment has been switched off, wait at
least 5 seconds before switching it on again!
34
Entering the service mode
34.1
When switching the main switch on, press the RESET button on the
external display for at least 5 seconds.
Ö
Signal 1 (ready for operation) flashes quickly (25 Hz)
34.2
As soon as signal 1 flashes, release the RESET button.
Ö
Signal 1 flashes quickly (25 Hz)
Briefly press the RESET button to start the motor.
The motor is stopped by pressing once again.
In case of a malfunction of the motor monitoring system (short-circuit
monitoring and monitoring of the running of the motor) the electronic
systems will not allow the motor to start.
The motor can be switched on and off at will by briefly pressing the
RESET button.
Pressing the RESET button for approximately 5 seconds will change the
service mode from motor monitoring to testing the inlets and outlets.
(Release the RESET button after hearing a beep).
Ö
Signal 1 flashes; signals 2 and 3 are steadily illuminated
Procedure for testing the inlets and outlets – see chapter 18 (annual
inspection).
Press the RESET button once again for approximately 4 seconds to end
the service mode.
Ö
Signal 3 flashes (25 Hz):
The equipment switches from service mode to normal operation
Ö
Signal 1 is permanently on
35
-
40
Please contact your service technician if the following
malfunction messages appear:
35
Malfunction in the short-circuit monitoring
36
Malfunction in the monitoring of the running of the motor
37
Motor malfunction upon start-up
38
Current consumption of the motor when running is too high
39
Power supply to motor interrupted
40
Short-circuit of motor power supply
Service mode
Practice personnel, technicians