The LED indicator on  the back of the light head supplies the following information:

 

 LED green:                 100%   -   50%   remain capacity
 LED orange:                50%    -   20%   remain capacity
 LED red:                      20%    -   10%   remain capacity
 LED red blinking:       10%    -     0%  remain capacity 

Note: These values are guiding values only and depend very much on water 
temperatures and the type of battery tank used! The values shown above were 
measured at a water temperature of 20°Celsius. In colder water (for instance 
10°Celsius or less) the LED light will go from green to orange in just a few minutes. 
This doesn’t mean the capacity of the battery tank is decreased to 50%, though 
the battery tank capicity reduces slightly in cold temperatures <10

Turn the cable connector a quarter turn to the left (anti clockwise) and pull it straight out of 
the battery pack connector. Before reassembly inspect and clean the O-rings, or replace 
the O-rings when damaged or deformed and apply a thin layer of silicone grease. Insert 
the connector fully into the battery pack connector and turn it a quarter turn to the right 
(clockwise), until it locks firmly into place. 

       

       The LED indicator on the light head 

       Disconnecting the light head

       
   

        Signal option

* The S.O.S. flash should only to be used in case of an emergency!

°C.

           

5

Beacon flash:

turn the switch 

within 1 second from position 2 to position 1 and back to 

position 2.

Strobe flash:

turn the switch for a second time 

within 1 second from position 2 to 

position 1 and back to position 2.

S.O.S. flash:

turn the switch for a third time 

within 1 second from position 2 to position 1 

and back to position 2.

From Beacon 
flash to Strobe:

when in Beacon flash position, turn the switch 

within 1 second from position 

2 to position 1 and back to position 2.

From Strobe to 
S.O.S.:

when in strobe flash position, turn the switch 

within 1 second from position 2 

to position 1 and back to position 2. 

Exit from any 
signal option:

turn off the dive light or turn the switch to 

position 1 for more than 1 second.

6

7

ENG

7

Summary of Contents for KL1242 LED2400/5100

Page 1: ...00 Battery Tank PR1204 PR1209 PR1213 Battery Tank FX1204 FX1209 METALSUB KABELLAMP KL1242 LED2400 5100 Bedieningshandleiding User manual METALSUB CABLE LIGHT KL1242 LED2400 6350 Bedieningshandleiding...

Page 2: ......

Page 3: ...Charging the battery pack 5 Deep discharge protection 6 7 The LED indicator on the light head 7 7 Connection of the battery tank onto tank or BCD 8 Technical information 9 Warranty 20 Connecting the...

Page 4: ...vent overheating in case the light switches on due to accidental impact or mishandling To prevent short circuiting it is essential to only connect the light head with the battery pack using the suppli...

Page 5: ...tlets with a voltage between 100 and 240 Vac The battery pack is delivered uncharged so it is important to charge the battery pack completely with a full charge cycle Make sure that the connector is c...

Page 6: ...in the counter connector socket on the battery pack The connection is made with a little inward push followed by a quarter turn to the right Disconnecting is done by performing the same sequence in r...

Page 7: ...when damaged or deformed and apply a thin layer of silicone grease Insert the connector fully into the battery pack connector and turn it a quarter turn to the right clockwise until it locks rmly int...

Page 8: ...ank belt of your BCD by guiding the belt through the slots in the tank plate see gure Subsequently t the BCD tank belt with the attached tank plate onto the scuba tank Now you can connect the battery...

Page 9: ...Ah 12 Volt 13 Ah Charger MP1100 MP2500 MP2500 MP2500 Charging time appr 2 hours appr 4 5 hours appr 7 hours Capacity with 2400 Lumen LED HEAD appr 110 min appr 270 min appr 400 min Capacity with 6350...

Page 10: ...10...

Page 11: ...t opladen van de accutank 13 Diepontladingsbeveiliging 14 15 De LED indicatie 15 15 Montage van de accutank aan de perslucht es 16 Technische informatie 17 Garantie 20 Het koppelen van de lamp aan de...

Page 12: ...lampkop ontkoppeld is van het accupack om brand of oververhitting te voorkomen Om kortsluiting te voorkomen is het noodzakelijk de accutank af te sluiten met de meegeleverde tankplug gen Gebruik alti...

Page 13: ...der te worden opgeladen Het opladen van de accutank De accutank wordt ongeladen geleverd en dient voor het gebruik opgeladen te worden Controleer of de laadplug en de contrastekker op de accutank droo...

Page 14: ...ken en een kwart slag naar rechts te draaien Het ontkoppelen van de lamp van de accutank geschiedt in omgekeerde volgorde Bij het koppelen van de lamp aan de accutank de stekker en contrastekker indie...

Page 15: ...en ca 100 50 batterij capaciteit LED oranje ca 50 20 batterij capaciteit LED rood ca 20 10 batterij capaciteit LED rood knipperen ca 10 0 batterij capaciteit Noot deze waarden zijn sterk afhankelijk v...

Page 16: ...tankplaat te vlechten guur A De accutank kan vervolgens bij voorkeur met de stroomaansluiting naar boven gericht op de tankplaat worden geklikt door middel van het METALSUB KLIKSYSTEEM Plaats daartoe...

Page 17: ...rtemperatuur 5700K 5700K Traploos dimbaar 100 0 100 0 Kabellengte 100 cm 100 cm Maximale druktest 25 bar 25 bar Accutank PR1204 FX1204 PR1210 FX1210 PR1213 Materiaal aluminium aluminium aluminium Afme...

Page 18: ...18...

Page 19: ...19...

Page 20: ...n aankoop Mits de duiklamp gebruikt en behandeld is overeenkomstig de bedieningshandleiding en onder overlegging van uw aankoopnota zullen gedurende 24 maanden na aankoop die delen gratis vervangen of...

Reviews: