7
Low installation
scheme
1 interlocking valve
2 reduction valve
3 Non-return valve
4 Mixing unit /pipe
CW cold water
HW hot water
Pict. 4
CONNECTION TO ELECTRIC POWER SUPPLY
Low capacity water heater is connected to power supply only
if tank is previously filled with water. Copnnection is made by valid
standards for electrical installations. Installation is done by the power
supply cable PP/J 3x1 with cast plug and ground protection. The ap-
pliance has to be mounted in the way that plug is accessible (to be
unplugged if needed)
WARNING:
before any intervention to the water heater it must be
unplugged from the power supply.
USE AND CARE
Switch on the heating of water by turning the button of the
regulator to a certain position, depending on desired temperature
Maximum water heating temperature is 75°C. The thermoregulator
switches off the heating automatically when desired temperature is
reached. During the heating the signal lamp is on, it goes off when
desired temperature is reached. If the temperature should be main-
tained, the thermoregulator button should be kept in positi8on pre-
viously set.
If connection cable is damaged only the producer, or its tech-
nical service or specialized person should replace it.
From time to time drops of water may come out from the
fitting pipe. This phenomenon can’t be prevented, therefore avoid
H.W.
C.W.