Installers manual 10.03.02-R03 (201058) EN SDA-04 (SW 5.xx) - SDA-04DCB2 (SW 22.00)
P
age 18 of 55
7.2
Parameter overview (end) user
The following parameters can be accessed by the (end) user and changed or checked:
Note: Most parameters have a value that is set at the factory. In case of a set
parameter it is marked red, underlined and placed between brackets:
(0)
.
A number indicates that this value can be changed. Two dashes mean that
something must be completed, four dashes mean that a value is expected.
Parameter 0
:
(----)
Log in to the controller (for authorised personnel only)
(----)
Enter your 4-digit login here to access the installation menu
Parameter 1
:
(2)
“remain-open” time after reaching the half-open (pedestrian) position
This is the time that elapses between the moment the door arrives at the partly or
half open position and begins the movement to return to the closed position.
For pulse open/close, the door will undertake this action immediately. Otherwise,
the door will close automatically after a set period of time has elapsed, which is
settable like shown below.
0 - 99
= number of seconds the door will remain open before closing automatically.
t0
= Pulse open/pulse closed, the door stays open until the next operation action
t1
= Pulse open/pulse closed, the door closes when Timer 1 has counted down to zero
(parameter 3)
t2
= Pulse open/pulse closed, the door closes when Timer 2 has counted down to zero
(parameter 4)
Parameter 2
:
(2)
“remain-open” time after reaching the full-open (vehicles) position
This is the time that elapses between the moment the door arrives at the fully or
completely open position and begins the movement to return to the closed
position. For pulse open/close, the door will undertake this action immediately.
Otherwise, the door will close automatically after a set period of time has elapsed,
which is settable like shown below.
0 - 99
= number of seconds the door will remain open before closing automatically.
t0
= Pulse open/pulse closed, the door stays open until the next operation action
t1
= Pulse open/pulse closed, the door closes when Timer 1 has counted down to zero
(parameter 3)
t2
= Pulse open/pulse closed, the door closes when Timer 2 has counted down to zero
(parameter 4)
Parameter 3
:
(0)
Timer 1
Adjustable timer (0 seconds - 10 minutes) to be used for a number of timer
controlled actions such as temporarily disabling the interlock function or cancelling
the open position in toggle mode.
0
= Factory default, timer is off
0.01- 10.00 = Adjustable time in minutes and seconds which serves as the starting point for the
timer to count down from
Summary of Contents for MDA120
Page 42: ...Installers manual 10 03 02 R03 201058 EN SDA 04 SW 5 xx SDA 04DCB2 SW 22 00 Page 42 of 55...
Page 43: ...Installers manual 10 03 02 R03 201058 EN SDA 04 SW 5 xx SDA 04DCB2 SW 22 00 Page 43 of 55...
Page 44: ...Installers manual 10 03 02 R03 201058 EN SDA 04 SW 5 xx SDA 04DCB2 SW 22 00 Page 44 of 55...
Page 45: ...Installers manual 10 03 02 R03 201058 EN SDA 04 SW 5 xx SDA 04DCB2 SW 22 00 Page 45 of 55...
Page 46: ...Installers manual 10 03 02 R03 201058 EN SDA 04 SW 5 xx SDA 04DCB2 SW 22 00 Page 46 of 55...
Page 47: ...Installers manual 10 03 02 R03 201058 EN SDA 04 SW 5 xx SDA 04DCB2 SW 22 00 Page 47 of 55...
Page 48: ...Installers manual 10 03 02 R03 201058 EN SDA 04 SW 5 xx SDA 04DCB2 SW 22 00 Page 48 of 55...
Page 49: ...Installers manual 10 03 02 R03 201058 EN SDA 04 SW 5 xx SDA 04DCB2 SW 22 00 Page 49 of 55...
Page 50: ...Installers manual 10 03 02 R03 201058 EN SDA 04 SW 5 xx SDA 04DCB2 SW 22 00 Page 50 of 55...
Page 51: ...Installers manual 10 03 02 R03 201058 EN SDA 04 SW 5 xx SDA 04DCB2 SW 22 00 Page 51 of 55...
Page 52: ...Installers manual 10 03 02 R03 201058 EN SDA 04 SW 5 xx SDA 04DCB2 SW 22 00 Page 52 of 55...
Page 53: ...Installers manual 10 03 02 R03 201058 EN SDA 04 SW 5 xx SDA 04DCB2 SW 22 00 Page 53 of 55...
Page 54: ...Installers manual 10 03 02 R03 201058 EN SDA 04 SW 5 xx SDA 04DCB2 SW 22 00 Page 54 of 55...
Page 55: ...Installers manual 10 03 02 R03 201058 EN SDA 04 SW 5 xx SDA 04DCB2 SW 22 00 Page 55 of 55...