ENGLISH
37
16. Technical Data
PK 255 2,5 WN
PK 255 3,4 DN
Voltage
230 V / 1~50 Hz
400 V / 3~50 Hz
Nominal current
A
11.1
6,3
Fuse protection min.
A
1 × 16 (time-lag)
3 × 16 (time-lag)
Protection class
IP 54
IP 54
Motor speed
min
-1
2800
2800
Motor power
Input power P
1
(S6 40%)
Output power P
2
(S6 40%)
kW
kW
2,5
1,9
3,4
2,5
Saw blade cutting speed approx.
m/s
50
50
Saw blade diameter (outer)
mm
250
250
Arbor bore
mm
30
30
Cutting depth
saw blade vertical
at 45
saw blade tilt
mm
mm
0 ... 80
0 ... 53
0 ... 80
0 ... 53
Dimensions
Saw table length
width saw table
Table extension length
Table extension width
Height (saw table)
overall height
mm
mm
mm
mm
mm
mm
790
665
420
345
850
1020
790
665
420
345
850
1020
Weight (complete approx.)
kg
74
74
Sound power level according to DIN EN 1870-1(2007) and
ISO 7960:1995 Addendum A*
no-load
when sawing
Uncertainty K
dB (A)
dB (A)
dB (A)
86,2
97,2
4,0
86,9
101,2
4,0
Emission sound power level according to
DIN EN 1870-1(2007) and ISO 7960:1995 Addendum A*
no-load
when sawing
Uncertainty K
dB (A)
dB (A)
dB (A)
79,0
95,2
4,0
76,4
94,9
4,0
Ambient temperature range
C
–10 … +40
–10 … +40
Extension cable – min. lead cross section
Length of cable: 10 m
Length of cable: 25 m
Length of cable: 50 m
mm
2
mm
2
mm
2
3 × 1.5
3 × 2.5
–
3 × 2.5
3 × 2.5
–
* The values stated are emission values and as such do not necessarily constitute values which are safe for the workplace. Alt-
hough there is a correlation between emission levels and environmental impact levels, whether further precautions are neces-
sary cannot be derived from this. Factors influencing the actually present environmental impact level in the workplace include the
characteristics of the work area and other noise sources, i.e. the number of machines and other neighbouring work processes.
Also, permissible workplace values may vary from country to country. This information is intended to assist the user in his esti-
mate of hazards and risks.