background image

ENGLISH

en

10

– do not have adequate experience and/or 

knowledge in handling the pump; or

– have not read and understood the operat-

ing instructions.

Children should be supervised to ensure that 

they do not play with the device.

The manufacturer assumes no liability for 

damage caused by unspecified use.

Unspecified use, modification of the pump or 

use of parts that have not been tested and 

approved by the manufacturer can cause un-

foreseeable damage!

3.2

General safety instructions 

– When using this pump, observe the follow-

ing safety instructions to exclude the risk of 

personal injury or material damage. 

– Follow the legal guidelines or accident pre-

vention regulations for using submersible 

pumps.

– When the pump is being used in swimming 

pools, garden ponds and in the protected 

areas around them, the regulations must 

be observed in accordance with IEC 

60364-7-702.

All national regulations relating to the safe 

operation of submersible pumps must also 

be followed.

– The pump must be protected by a residual 

current device (RCD) with a trip current of 

max 30 mA.

A

General danger! 

Do not operate the pump if anyone is in con-

tact with the pumping media (e.g. in a swim-

ming pool or garden pond)!

The following residual risks essentially re-

main when operating submersible pumps 

and cannot be fully eliminated – even by em-

ploying safety devices. 

A

Danger from the environment! 

Do not use the pump in hazardous locations 

or near inflammable liquids and gases! 

B

Danger! Risk of electric shock! 

Do not touch the plug with wet hands! To dis-

connect, always pull on the plug, not the pow-

er cable.

Connect only to an earthed outlet that is 

properly installed, earthed and tested. Mains 

voltage and fuse protection must correspond 

to those stated in the 'Technical Specifica-

tions'.

Always lift and transport the pump by the 

handle, never by the power cable or dis-

charge hose.

Extension cables must have sufficient con-

ductor cross sections. Unroll cable reels fully. 

Do not buckle, squeeze, drag or drive over 

power cable or extension cables; protect 

from sharp edges, oil and heat. 

Place extension cable so that it cannot get into 

the fluid to be pumped. 

Always unplug before servicing the pump. 

B

Risk of electric shock from pump 

faults! 

Before each use, check the equipment - es-

pecially the power and extension cables, 

power plug and float switch - for possible 

damage. Risk of fatal electric shock! 

Do not attempt to repair the pump yourself! 

When repaired inexpertly, there is a risk of 

liquid entering the electrical parts of the 

pump. 

A

Caution! 

To avoid water damage, e.g. flooded rooms, 

caused by pump malfunctions or defects: 

provide for suitable safety measures such as 

the following:

– alarm  or

– collection tank with monitoring.

The manufacturer is not liable for any dam-

age caused by:

– improper use of the pump;

– failure to operate and store the pump in a 

frost-free environment;

– unauthorised modification of the pump (re-

pairs to electrical equipment may only be 

carried out by qualified electricians!);

– use of spare parts which have not been 

tested and approved by the manufacturer; 

or

– use of unsuitable installation materials (fit-

tings, connection lines etc.). 

Suitable installation materials:

– pressure-resistant (min. 10 bar)

– heat-resistant (min. 100°C).

4.1

Connecting the discharge line

Connecting thread details: see Technical 

Specifications.

4.

Assembly and Installation

Summary of Contents for DP 18-5 SA

Page 1: ...es Manual original 26 pt Manual original 32 sv Originalbruksanvisning 38 fi Alkuper inen k ytt opas 43 da Original brugsanvisning 48 el 53 ru 59 sl Originalna navodila za uporabo 65 et Kasutusjuhend 7...

Page 2: ...DP 18 5 SA DP 28 10 S Inox SP 24 46 SG SP 28 50 S Inox 1 1 2 2 3 3 4 1 2 3 4 4 5 6 7 5 6 7 5 6 5 6 7 1 2 3 4 7 2...

Page 3: ...ining purposes on construction sites in agriculture and in domestic homes and gar dens SP 24 46 SG and SP 28 50 S Inox are also intended for draining wastewater both in in dustrial and domestic enviro...

Page 4: ...pow er cable Connect only to an earthed outlet that is properly installed earthed and tested Mains voltage and fuse protection must correspond to those stated in the Technical Specifica tions Always...

Page 5: ...are not designed to withstand the tensile stress produced by the weight of the pump 4 4 Installing the pump 1 Submerge pump at a slight angle to avoid creating an air cushion on the underside which wo...

Page 6: ...n should only be carried out by qualified specialists 6 1 Regular care Regular care is required for the pump to func tion perfectly at all times This also applies if the pump is not switched on for ex...

Page 7: ...king air Ensure there is a sufficient water sup ply Foreign objects are present clean pump Manual mode has been set shallow water suctioning Hold pump at an angle when submerg ing Pump runs continuous...

Page 8: ...0 m 12 17 9 12 bar 1 2 1 7 0 9 1 2 m 7 7 7 7 mm 5 10 46 50 C 35 35 50 35 35 50 IP 68 68 68 68 m 10 10 10 10 1 1 2 2 mm 416 465 412 537 kg 10 18 5 18 19 3 max Hmax max EN 60335 1 EN 60335 2 41 2006 95...