background image

Betriebsanleitung und Ersatzteilliste
Kreiselpumpen

Operating Instructions and Spare Parts List
Centrifugal Pump

P 600/1600 W
P 600/1600 D

D

GB

Achtung!

Lesen Sie diese Anleitung vor der Installation und Inbetriebnahme aufmerksam durch.

Attention!

Carefully read through these instructions prior to installation and commissioning.

D

GB

1151152070 / D/GB / 3907 - 2.1

Summary of Contents for 1600 D

Page 1: ...d Spare Parts List Centrifugal Pump P 600 1600 W P 600 1600 D D GB Achtung Lesen Sie diese Anleitung vor der Installation und Inbetriebnahme aufmerksam durch Attention Carefully read through these instructions prior to installation and commissioning D GB 1151152070 D GB 3907 2 1 ...

Page 2: ...asser über die Wasserablaufschraube ablaufen lassen 8 Wasserablaufschraube einschrauben 9 Sauberes Wasser einfüllen bis die Pumpe gefüllt ist 10 Wassereinfüllschraube einschrauben 11 Druckleitung Wasserhahn gering öffnen 12 Netzstecker einstecken und Pumpe einschalten 13 Eventuell den Vorgang nochmals wiederholen Sollten Sie diese technischen Hinweise nicht beachten kann es zur Schaumbildung im Ge...

Page 3: ...ose 230 V 50 Hz angeschlossen werden Absicherung mindestens 16 A Die Elektra Beckum Kreiselpumpe P 600 1600 D ist schutzgeerdet und darf nur an einer CEE Steckdose 400 V 50 Hz angeschlossen werden Absicherung mindestens 16 A Beschädigte Anschlußleitungen müssen durch eine Elektrofachkraft ausgetauscht werden Der Betrieb mit beschädigten Anschlußleitungen ist lebensgefährlich Mindestqualität H 07 R...

Page 4: ...imengungen wie Sand Schmutz oder andere Feststoffe im Wasser müssen unbedingt durch ein in die Saugleitung einzubauender Filter von der Pumpe ferngehalten werden Dieser Filter wird zwischen Saugleitung und Rückschlagventil montiert Im Programm der Elektra Beckum AG finden Sie verschiedene Filter für Hauswasserversorgungsanlagen Alle Verschraubungselemente und Anschlußstutzen sollten mit Teflonband...

Page 5: ...urch eine Elektrofachkraft vorgenommen werden Störungen und ihre Beseitigung Beseitigung Die Saughöhe darf höchstens 9 Meter betragen Rückschlagventil gangbar machen oder erneuern Saugleitung abdichten Gleitringdichtung erneuern Pumpe demontieren reinigen und defekte Teile erneuern Gleitringdichtung erneuern Ursache Saughöhe zu groß Rückschlagventil klemmt Saugleitung undicht Gleitringdichtung und...

Page 6: ...2238 15 Klemmbrett 134 915 2246 16 Klemmkasten 230 V 134 915 2254 Pos Benennung Art Nr 16 Klemmkasten 400 V 134 915 2440 17 Spritzring 134 915 2262 18 Sechskantmutter selbsts M10 620 200 2313 19 Rillenkugellager 6204 710 001 6820 20 Rillenkugellager 6204 710 001 6820 21 Distanzscheibe 134 915 2270 22 Zuganker M5x150 134 915 2289 23 Kondensator 35 μF 805 015 2295 24 Verschlußschraube 1 4 610 914 91...

Page 7: ...rain out via the water drain screw 8 Screw in the water drain screw 9 Fill with clean water until the pump is full 10 Screw in the water filler screw 11 Slightly open the pressure line water tap 12 Connect the mains plug and switch on the pump 13 Repeat the steps again if required Failure to observe these technical instructions may lead to foaming in the machine This prevents the intake of water t...

Page 8: ...t legislation If in doubt consult a qualified electrician A defective pump should be taken out of service immediately as water leakage may cause damages Pull plug from socket if unit is not in use holidays weekend homes etc Children and juveniles should not operated this device Use only genuine Elektra Beckum spare parts for repairs 1 Specifications P 600 1600 W P 600 1600 D Capacity max 9 m3 h ma...

Page 9: ...for suitable filters offered by Elektra Beckum If the pump does not start when new or not having been in use for a longer period turn pump manually With the help of a screw driver put through the fan cover turn motor fan until shaft has worked free Caution Always disconnect from power before attempting to free shaft Note Without a check valve the water level in the suction line can drop This can c...

Page 10: ...ress in suction line Tighten and or seal Suction line kinked Straighten suction line so that there are no sharp bends Duocone seal worn Replace Suction strainer clogged Clean Pump hums Plastic parts warped Disassemble clean and replace defective parts Impeller clogged Shaft locked Water emerging between Duocone seal worn Replace motor and pump body 7 Problems If the pump does not prime check if su...

Page 11: ...nal board 1349152246 16 Terminal box 1 230V 1349152254 Item Description Stock no 16 Terminal box 3 400V 1349152240 17 Splash ring 1349152262 18 Hex nut self locking M 10 6202002313 19 Grooved roller bearing 6204 7100016820 20 Grooved roller bearing 6204 7100016820 21 Spacer 1349152270 22 Tie rod motor M 5x150 1349152289 23 Capacitor 35 μF 8050152295 24 Drain plug 1 4 6109149193 25 Drain plug 1 4 6...

Page 12: ...powiada wymogom nastĊpujących norm wedáug ustaleĔ wytycznych sprawozdanie z kontroli technicznej przeprowadzone przez Zmierzony Gwarantowany poziom ciĞnienia akustycznego EL HU ǻǾȁȍȈǾ ǹȃȉǿȈȉȅǿȋǼǿǹȈ MEGEGYEZėSÉGI NYILATKOZAT ǻȘȜȫȞȠȣμİ μİ ȚįȓĮ İȣșȪȞȘ ȩIJȚ IJȠ ʌȡȠȧȩȞ ĮȣIJȩ ĮȞIJȚıIJȠȚȤİȓ ıIJȚȢ ĮțȩȜȠȣșİȢ ʌȡȠįȚĮȖȡĮijȑȢ ıȪμijȦȞĮ μİ IJȚȢ įȚĮIJȐȟİȚȢ IJȦȞ ȠįȘȖȚȫȞ ǼțșİıȘ İȜİȖȤȠȣ ʌȡĮȖμĮIJȠʌȠȚȠȪμİȞȠȢ Įʌȩ IJȠ ȂİIJȡȘșİȓıĮ ǼȖȖ...