11
English
2. Filter-Regulator-Lubricator
○
Use a regulator with a pressure range of 0–120 psi
(0–8.3 bar 0–8.5 kgf/cm
2
).
○
Filter-regulator-lubricator units supply an optimum
condition for the Nailer and extend the Nailer life.
These units should always be used.
Filter ............ The
fi
lter removes moisture and dirt
mixed in compressed air.
Drain daily unless
fi
tted with an
automatic drain.
Keep the
fi
lter clean by regular
maintenance.
Regulator ......The regulator controls the operating
pressure for safe operation of the Nailer.
Inspect the regulator before operation to
be sure it operates properly.
Lubricator .... The lubricator supplies an oil mist to the
Nailer.
Inspect the lubricator before operation
to be sure the supply of lubricant is
adequate.
Use metabo HPT pneumatic tool
lubricant.
Nailer Side
Filter
Lubricator
Compressor Side
Regulator
3. Air
hose
Compressed air supply hoses shall have a minimum
working pressure rating equal to or greater than the
pressure from the power source if a regulator fails, or
150 psi (10.4 bar 10.6 kgf/cm
2
), whichever is greater.
4. Air
consumption
Using the Air consumption table and the Air
compressor size formula,
fi
nd a correct compressor
size.
Air consumption table
Operating pressure
psi
(bar)
(kgf/cm
2
)
80
(5.5)
(5.6)
90
(6.2)
(6.3)
100
(6.9)
(7)
Air consumption
ft
3
/cycle
(Itr/cycle)
.062
(1.7)
.075
(2.1)
.088
(2.5)
Air compressor size formula
Amount of air required
=number of Nailers
× average nails driven each minute per Nailer
× air consumption at given air pressure
× safety factor (always 1.2)
Example: 2 Nailers operating at 100 psi driving 30
nails per minute
Amount of air required
=2 × 30 × .088 (2.5) × 1.2
=6.3 CFM (ft
3
/min) (180 ltr/min)
After making the calculations as shown above, you
should
fi
nd a compressor providing 6.3 CFM of air
that is required.
LUBRICATION
It is important that the Nailer be properly lubricated.
Without proper lubrication, the Nailer will not work
properly and parts will wear prematurely.
○
Use metabo HPT pneumatic tool lubricant.
Do not use detergent oil or additives. These lubricants
will harm the O-rings and other rubber parts. This will
cause the Nailer to malfunction.
○
Filter-regulator-lubricator units should always be
used.
Keep the lubricator
fi
lled with metabo HPT pneumatic
tool lubricant.
○
If a lubricator is not available, supply 5–10 drops of
metabo HPT pneumatic tool lubricant into the air plug
on the Nailer twice a day.
COLD WEATHER CARE
○
Do not store the Nailer in a cold weather environment.
Keep the Nailer in a warm area until beginning the
work.
○
If the Nailer is already cold, bring it in a warm area
and allow the Nailer to warm up before use.
Reduce the air pressure to 64 psi (4.4 bar
4.5 kgf/cm
2
).
Remove all nails from the Nailer.
Connect the air hose and free-
fi
re (blank-
fi
re) the
Nailer.
The lowered air pressure will be enough to free-
fi
re the Nailer.
Slow speed operation tends to warm up the
moving part.
CAUTION
●
Do not free-
fi
re the Nailer at high pressure.
000Book̲NV83A5̲US̲metabo.indb 11
000Book̲NV83A5̲US̲metabo.indb 11
2022/05/19 11:02:36
2022/05/19 11:02:36