Faults
Use only MESTO spare parts and accessories
(
→
Fig. on page 2)
.
Fault
Cause
Remedy
No pressure builds up in
the device
The pump is not screwed on
tightly.
Screw the pump on tightly.
O-ring [17] on the pump is
faulty.
(Fig. 15)
Replace the O-ring.
Diaphragm [18] is defective.
(Fig. 15)
Replace the diaphragm.
Liquid flows out of the
pump
Valve disc [21] dirty or
defective.
(Fig. 19)
Clean or replace the valve disc.
No tank pressure
indication on the piston
pressure gauge,
Safety valves blow off too
early.
Piston pressure gauge [14] is
defective
Have the piston pressure
gauge repaired.
The nozzle does not
spray even though
pressure is present
Filter [20]
(Fig. 18)
and / or
nozzle [13]
(Fig. 17)
is clogged.
Clean the filter or / and nozzle.
Only spray, no
atomization
Insert [12] is missing
(Fig. 17)
Position the insert in the nozzle
The shut-off valve does
not close.
Liquid emerges without
the lever being activated.
O-ring [22] of the pressure bolt
[23] not greased / lubricated.
(Fig. 20)
Defective pressure bolt [23] or
O-ring [22]
(Fig. 20)
Grease the O-ring of the
pressure bolt
(dismantle or
assemble the pump
→
section
"Care and maintenance")
Replace the pressure bolt or O-
ring.
Contact address for additional information
→
see title page
.
Summary of Contents for HERBI 3232U
Page 4: ...4 8 9 10 11 12 13 14 15 16 7 16 2 14 7 16 2 7 16 5 8 7 9 1 1 3232U 2 3232 18 17...
Page 5: ...5 16 17 18 19 20 20 20 19 16 2 19 12 13 13 12 8 5 9 8 21 22 23 3232U 3232 16 3232U 3232 9...
Page 55: ...55 GR MESTO MESTO PICO 3232 HERBI 3232U HERBI 3232U BVL 30 C STO...
Page 56: ...56 GR 1 MESTO 1...
Page 60: ...60 GR 2 5 MESTO 2 17 15 18 15 21 19 14 20 18 13 17 12 17 22 23 20 23 22 20...