18
Faults
Use only MESTO spare parts and accessories
(→ fig. on page 2).
Fault
Cause
Remedy
No pressure builds up in
the device
The pump is not screwed
on tightly.
Screw the pump on tightly.
O-ring [13] on the pump is
faulty.
(Fig. 15)
Replace the O-ring.
Diaphragm [14] is defecti-
ve.
(Fig. 16)
Replace the diaphragm.
Liquid flows out of the
pump
Valve disc [15] dirty or
defective.
(Fig. 17)
Clean or replace the valve disc.
Piston pressure gauge
does not indicate any tank
pressure.
Safety valve blows off too
early.
Piston pressure gauge [16]
is defective.
(Fig. 18)
Replace the piston pressure
gauge.
The nozzle does not spray
even though pressure is
present
Nozzle [17]
(Fig. 19)
or /
and filter [18] (
Fig. 20)
is
clogged.
Clean the filter or / and nozzle.
The shut-off valve does not
close.
Liquid emerges without the
lever being activated.
O-ring [23] of the pressure
bolt [24] is not greased /
lubricated.
(Fig. 22)
Faulty O-ring [23] or pres-
sure bolt [24].
(Fig. 21)
Grease the O-ring of the pressu-
re bolt (dismantle shut-off valve
→ section „Care and mainte-
nance“)
Replace O-ring or pressure bolt.
Contact address for additional information
→ Title page.
GB
IRL
AUS
USA
NZ
CDN
IND
Summary of Contents for CLEANER 3270PE
Page 3: ...3 1a 1b 2 3 4 5 6 7 7 6 5 3 3 9 1 3 2 7 5 6 4 10 2 11 1 1 3 2 7 5 6 4 8 3...
Page 4: ...4 8 9 10 11 12 13 14 15 16 2 10 8 6 2 5 1 2 13 13 14 14 12b 12a 6 6 5 4...
Page 5: ...5 17 18 19 20 21 22 17 17 5 18 20 19 15 2 16 6 21 23 22 24 19 25 5...
Page 98: ...98 1 MESTO 1 GR...
Page 102: ...102 MESTO 2 13 15 14 16 15 17 16 18 17 19 18 20 23 24 22 23 24 21 GR 2 5...
Page 104: ...104...