18
Fault
Cause
Remedy
No pressure builds up in
the device.
The pump is not screwed
on tightly.
Screw the pump on tightly.
O-ring [13] on the pump is
faulty.
)LJ
Replace the O-ring.
Diaphragm [14] is defecti-
ve.
(Fig. 16)
Replace the diaphragm.
/LTXLGÀRZVRXWRIWKH
pump.
Valve disc [15] dirty or
defective.
(Fig. 17)
Clean or replace the valve disc.
Piston pressure gauge
does not indicate any tank
pressure.
6DIHW\YDOYHEORZVRႇWRR
early.
Piston pressure gauge [16]
is defective.
(Fig. 18)
Replace the piston pressure
gauge.
The nozzle does not spray
even though pressure is
present.
Nozzle [17]
(Fig. 19)
or /
DQG¿OWHU>@
Fig. 20)
is
clogged.
&OHDQWKH¿OWHURUDQGQR]]OH
7KHVKXWRႇYDOYHGRHVQRW
close.
Liquid emerges without the
lever being activated.
O-rings [23] of the pressu-
re bolt [24] are not grea-
sed / lubricated.
(Fig. 22)
Faulty O-rings [23] or pres-
sure bolt [24].
(Fig. 22)
Grease the O-rings of the
pressure bolt (dismantle shut-
RႇYDOYH
ĺVHFWLRQÄ&DUHDQG
PDLQWHQDQFH³
Replace O-ring or pressure bolt.
EN ENGLISH
Faults
&RQWDFWDGGUHVVIRUDGGLWLRQDOLQIRUPDWLRQĺVHHWLWOHSDJH
Use only original spare and accessory parts.