20)  REPLACEMENT PARTS GUIDE 

 

ITE

M# 

PART # 

DESCRIPTION 

 

ITE

M# 

PART # 

DESCRIPTION 

30333110  Valve VR8205M-2971 @ 10” W.C. – Propane Gas 

 

17 

43908010  Frame Assembly 

(1 Burner Unit) 

30333120  Valve VR8205M-2989 @ 6” W.C. – Natural Gas 

 

18 

43908020  Frame Assembly 

(2 Burner Unit) 

30279000  Transformer AT120B1051 

 

19 

43908030  Frame Assembly 

(3 Burner Unit) 

30632030  Spark Module, Fenwal #35-605950-015 

 

20 

43908040  Frame Assembly 

(4 Burner Unit) 

30295020  Electrode PSE-GF9 

 

21 

03548000  Junction Box, 2 

x

 4 

x

 1½  

3056704 

Ignition Cable 7” 

 

22 

03606000  Cover Plate 

43856029  Burner Assembly Kit (Ignition Unit) 

 

23 

43849000  Ignition Control Bracket 

43856039  Burner Assembly Kit (2

nd

, 3

rd

, and 4

th

 Unit) 

 

24 

43872380  Orifice #38 for RD040, RD080, RD120, RD160 – Natural Gas 

43862010  Manifold for RD033, RD035, RD040 

 

25 

43872410  Orifice #41 for RD035, RD070, RD100, RD140 – Natural Gas 

10 

43862020  Manifold for RD060, RD066, RD070, RD080 

 

26 

43872980  Orifice 3/32” for RD030, RD060 – Natural Gas 

11 

43862030  Manifold for RD100, RD120 

 

27 

43872520  Orifice #52 for RD033, RD066, RD100, RD132 – Propane Gas 

12 

43862040  Manifold for RD132, RD140, RD160 

 

28 

43219040

 

Installation and Operation Manual  

(Not Shown)

 

13 

43847010  Reflector for RD033, RD035, RD040 

 

29 

42052030  Label - Connection Wire Diagram   

14 

43847020  Reflector for RD060, RD066, RD070, RD080 

30 

42849080  Label – Nameplate (Sterling) 

15 

43847030  Reflector for RD100, RD120 

30a 

42849081  Label – Nameplate (Mestik)

 

16 

43847040  Reflector for RD132, RD140, RD160 

30b 

42849082  Label – Nameplate (Beacon/Morris)

 

 

 

 

31 

43247070  Label – Clearances to Combustibles 

 

 

 

32 

42875000  Label -  General Warnings 

 

 

 

 

 

 

 

 

 

 

 
 

 
 
 
 

 
 

 
 

 

 
 
 
 
 

19 

 

 

IMPORTANT: 

  Please  order  by  Part  Number,  not  by  Item    

Number. 

 Refer to complete Model Number when ordering. 

 All replacement parts available when ordering. 

 
 

Screws,  nuts  and  washers  are  standard  hardware 
items and can be purchased at any local hardware 

store. 
 

 
ALL  ILLUSTRATIONS  ARE  INTENDED  TO  GIVE  THE 

GENERAL  IMPRESSION  OF  UNITS  ONLY.    WE 
RESERVE 

THE 

RIGHT 

TO 

ALTER 

ANY 

SPECIFICATION WITHOUT NOTICE 
 

 

Summary of Contents for R (B,S,M) D SERIES

Page 1: ...servicing this equipment In locations used for the storage of combustible materials signs must be posted to specify the maximum permissible stacking height to maintain the required clearances from the...

Page 2: ...the National Fuel Gas Code ANSI Z223 1 latest edition are available from the CSA at 8501 East Pleasant Valley Road Cleveland Ohio 44131 or 55 Scarsdale Road Don Mills Ontario M3B 2R3 All NFPA codes ar...

Page 3: ...regulations Every heater shall be located with respect to building construction and other equipment so as to permit access to the heater Each installer must follow the clearances to combustible mater...

Page 4: ...reas used for storage of combustible materials where they may be stacked below the heater NFPA54 requires that the installer must post signs that will specify the maximum permissible stacking height t...

Page 5: ...imum Clearances to Combustibles listed in the manual and on the heater at all times 4 MINIMUM CLEARANCES TO COMBUSTIBLES For maximum safety the building must be evaluated for hazards before installing...

Page 6: ...USTIBLES MODEL R B S M D Series Mounted Horizontally Mounted at 35 Angle Angle Mounting SIDES CEILING BELOW BELOW FRONT REAR w Standard Reflector w Reflector Extension w Standard Reflector w Reflector...

Page 7: ...S M D 140 N1C 140 000 4 41 n a 58 lbs 17 R B S M D 160 N1C 160 000 4 38 n a 58 lbs 18 R B S M D 033 L1C 33 000 1 n a 52 30 lbs 11 R B S M D 066 L1C 66 000 2 n a 52 35 lbs 13 R B S M D 100 L1C 99 000 3...

Page 8: ...the gas manifold assembly is on the lower side of the heater Coil chains No 2 or larger or rigid supports may be used to mount the heater which must be suspended from a permanent structure with adequa...

Page 9: ...ocated in accordance with the required clearances to combustibles below the heater as listed on the nameplate of the heater 3 Pipe joint compounds must be resistant to the action of liquefied petroleu...

Page 10: ...the heater must be released before proper heater operation 7 After all gas connections have been made make sure the heater and all gas outlets are turned off before the main gas supply is turned on Tu...

Page 11: ...stment is required remove the cover screw Using a small screwdriver turn the adjustment screw clockwise to increase or counter clockwise to decrease the gas pressure to burner Replace the cover screw...

Page 12: ...ve electrical circuit one that is not controlled by a light switch 4 The power supply to the unit should be protected with a fused disconnect switch or circuit breaker A service switch as required by...

Page 13: ...ATER PER THERMOSTAT B LINE VOLTAGE 120V THERMOSTAT CONNECTIONS MULTIPLE HEATERS PER THERMOSTAT C LOW VOLTAGE 24V THERMOSTAT CONNECTIONS MULTIPLE HEATERS PER THERMOSTAT POWER SUPPLIED FROM FAN CENTER R...

Page 14: ...and outlet vent area depending on height and temperature difference is as follows RD030 RD033 RD035 0 49 s f RD100 1 48 s f RD040 0 57 s f RD120 1 72 s f RD060 RD066 RD070 0 98 s f RD132 RD140 1 97 s...

Page 15: ...s before attempting to relight 6 The heater must be grounded Poor grounding will give nuisance lockouts particularly during momentary power interruptions 7 To shut down the heater turn off the gas and...

Page 16: ...er orifice and clean it thoroughly 4 Check the venturi opening to be sure it is clean If there is any evidence of dirt accumulation in the venturi remove it 15 BURNER OPERATION TROUBLESHOOTING A IGNIT...

Page 17: ...The thermostat sensing bulb is incorrectly placed The thermostat is out of calibration Conduct heat loss and add heaters or other source of heat as necessary Reposition as necessary for proper operat...

Page 18: ...Form 43219040 Oct 2013 C TROUBLESHOOTING CHART Continued 17...

Page 19: ...RD030 RD033 RD035 RD040 43822010 RD060 RD066 RD070 RD080 43822020 RD100 RD120 43822030 RD132 RD140 RD160 43822040 17 OPTIONAL PROTECTIVE REVERB SCREEN The optional protective Reverb Screen acts as a s...

Page 20: ...D060 RD066 RD070 RD080 26 43872980 Orifice 3 32 for RD030 RD060 Natural Gas 11 43862030 Manifold for RD100 RD120 27 43872520 Orifice 52 for RD033 RD066 RD100 RD132 Propane Gas 12 43862040 Manifold for...

Page 21: ...Form 43219040 Oct 2013 21 WARNINGS CARD This card is furnished with each heater Additional copies may be ordered under part no 43344970 20...

Reviews: