On a typical forced hot water system, connect return to inlet side of circulator and supply upstream of re-

motely operated valve. Unit may also be connected to mains of an existing loop system of sufficient capacity. 

Operation will be influenced by the system circulator and associated controls.

Installation of a pump and line voltage thermostat will provide the unit with its own “zone” control.

With the addition of a circulator pump, hot water storage tanks may be used (where codes permit) as a supply 

source if proper precautions are taken, and if realitively low water temperatures can be tolerated. Be sure tank 

can supply additional load of the Kickspace heater and 120°F water. Supply is taken from top of tank, and 

returns at the cold water inlet with a check valve. Do not return to bottom drain tapping.

Operation from steam boiler water is entirely possible as long as supply and return connection is installed be-

low level of water line on a steam boiler. This installation requires an optional circulator pump and line voltage 

thermostat. Check local building codes.

Model

Description

Part No.

42

84 120

Quick-Connect Hose Kit

HK-10

x

x

x

Model

Description

Part No.

42

84 120

Motor-Fan Assembly

BMKR02020-001

x

BMKR02020-002

x

BMKR02020-003

x

Standard Aquastat Assembly (120° – 105°F)

BMKR02024-001

x

x

BMKR02024-002

x

Low Temp. Aquastat Assembly (110° – 95°F)

BMKR0204-L01

x

x

BMKR0204-L02

x

Heating Element

BMKR02017-001

x

BMKR02017-002

x

J37R52064

x

2 Speed Fan Switch

J11R02029-001

x

x

x

Outlet Grille w/ screws (Model K only) (Black)

BMKR08778-B42

x

BMKR08778-B84

x

BMKR08778-B12

x

Louvered Front Panel (Model W only)

BMWR02172-001

x

BMWR02172-002

x

x

Louvered Front Panel (Model F only)

BMFR02165-001

x

BMFR02165-002

x

x

Louvered Front Panel (Model FK only)

FKR02437-001

x

FKR02437-002

x

x

Summary of Contents for Kickspace Series

Page 1: ...gh a flush mounted louvered front panel Type F is a surface mounted wall unit with the air discharged evenly through a louvered front panel in an upward direction All types have heating elements with...

Page 2: ...KICKSPACE MODEL 42 FIGURE 1 2 KICKSPACE MODEL 84 FIGURE 2 KICKSPACE MODEL 120 FIGURE 3 Dimensions shown in English and metric DIMENSIONAL DATA...

Page 3: ...ATION AND SERVICE IT IS RECOMMENDED THAT THIS ACCESS PANEL BE CONSTRUCTED SO ANNUAL CLEANING OF THE BLOWER FAN AND COIL FINS CAN BE EASILY ACCESSIBLE 3 At this location center and cut an opening in th...

Page 4: ...erated flow control or circuit setter can be placed between the two standard tee s in a one pipe system For consistent response of the reverse acting thermostat and effective outlet air temperature th...

Page 5: ...allation Figure 8 is a supply installation Figure 9 shows installation for the return side red ring between risers The return tee is installed opposite of the supply tee with the red ring between the...

Page 6: ...ower turns on check below for possible solutions a Water is not hot enough Check system water temp If radiant system low temperature aquastat may be needed b Water not circulating fast enough Kickspac...

Page 7: ...eck valve Do not return to bottom drain tapping Operation from steam boiler water is entirely possible as long as supply and return connection is installed be low level of water line on a steam boiler...

Page 8: ...anship of any installer of the Product This limited warranty is conditional upon a shipment to the Manufacturer of that part of the Product thought to be defective Goods can only be returned with prio...

Reviews: