Messtechnik U16/14-100k Manual Download Page 8

Date:
11/19/13

U16/14-100k

Page: 8

Manual

Error:

Possible reasons:

Solution:

Low-impedance at
input

Input wiring defective (if
system was used for 

immunity tests without 
external filter or over 

voltage at input)

Send in device to the 
manufacturer

 7 

Accessories / Options

Part

Order number

Comment

Optical fiber

LWL-1-xm

x = length in m, simplex

External batteries

BP-60-25

6V/2,5Ah

Connector cable for 

BP-60

SC-20-5m5m

Length approx. 20cm

Charger with 

connector plugs

CH1-5m

Standard charger

Input filter

FI-X-Y

X = ratio

y = frequency limit in MHz
(ask for details)

Output filter

FO-X-Y

X = ratio
y = frequency limit in MHz

(ask for details)

Manual

MA-

Ux/12-100k

German or english

Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 408­916­5750, www.reliantemc.com

 

Summary of Contents for U16/14-100k

Page 1: ...Manual BV15 Analog transmitter U16 14 100k Distributed by Reliant EMC LLC 3311 Lewis Ave Signal Hill CA 90755 408 916 5750 www reliantemc com...

Page 2: ...Distributed by Reliant EMC LLC 3311 Lewis Ave Signal Hill CA 90755 408 916 5750 www reliantemc com...

Page 3: ...n 5 4 External filters 5 4 1 Differentiation input vs output filter 5 5 Maintenance 6 6 Trouble shooting 7 7 Accessories Options 9 8 Contact 9 Appendix Details and operation A1 Distributed by Reliant...

Page 4: ...analog voltage signals Because of the optical transmission the system is very robust against EMS electromagnetic susceptibility It can withstand high electric and magnetic fields like they appear in...

Page 5: ...o its input impedance do not use an extension Notice the differentiation of input and output filters see chapter4 1 4 1 Differentiation input vs output filter If you want to transmit analog voltages f...

Page 6: ...rger to power the device inside the shielded room while EMI tests are running This might damage it Due to self discharge issues with NiMH batteries recharge batteries before use if the system has not...

Page 7: ...at transmitter and receiver recharge batteries Test source signal directly at the device under test Device cannot be turned on cannot be charged Batteries damaged Internal fuse is broke Charger or ca...

Page 8: ...r Comment Optical fiber LWL 1 xm x length in m simplex External batteries BP 60 25 6V 2 5Ah Connector cable for BP 60 SC 20 5m5m Length approx 20cm Charger with connector plugs CH1 5m Standard charger...

Page 9: ...onnectors switches Fig a 1 shows the front sides of transmitter left and receiver right with connectors power push button with control LED Pwr On Off battery information LED Info charge plug Charge op...

Page 10: ...el 2mm Hirschmann in the shown case Here the SD LED is integrated as well as the power switch At the rear side of the receiver the connectors for optical input and the power supply 6 8V 0 5A are place...

Page 11: ...r into account while setting checking your measurement device Turn on all devices no order to be recognized Communication between transmitter and receiver will be indicated by the Signal detect LED at...

Page 12: ...k messtechnik Others might lead to a damage of the system Only use battery packs and connector cables provided from mk messtechnik Other modules influence EMS performance and might damage the opto sys...

Reviews: