background image

 

 
                                                                                                                                                                                
                                                                                                                                                                  

 
 

                                                          

13 

 

Manual     IBRit

 

-

 

rf1

 

-

 

usb 

 

     7.   Guarantee 

 

The quality of this instrument is guaranteed for a period of 12 months from the date of delivery. This 
guarantee covers all materials and manufacturing defects. Our liability is confined to repair, or should we 
deem it necessary, replacing or crediting the goods. 
The following are not covered by the guarantee : 

‹

 

 Damages due to incorrect handling, 

‹

  Disregard of operating instructions, 

‹

  Tampering by unauthorised staff, 

‹

  Attempts by any unauthorised person to repair the instrument. 

 

In no case any consequences are covered by the guarantee which are connected either directly or 
indirectly to the instrument or its use. 
 
Notice : 

If returning the instrument under guarantee please use the original packaging. 

 

 

Should you detect an irregularity of any kind, please contact one of our authorised distributors or our 
Service department. 
 
 
 
 
D-36166 Haunetal, 24.04.2006  
 
 

I B R  Messtechnik GmbH & Co. KG 

 
 

A. Schneider 

Quality Assurance Manager 

 
 

 

 

Summary of Contents for IBRit-rf1 Series

Page 1: ...M e s s t e c h n i k Document No D1F604 001 Version April 2006 Copyright IBR Messtechnik GmbH Co KG INSTRUCTION MANUAL IBRit rf1 usb PC Station for wireless Data transmission ...

Page 2: ...dules with the programme IBR_SimKey 9 4 Confirmation signals of the IBRit rf1 gauge radio modules 10 5 Safety Instructions 11 6 Declaration of conformity 12 7 Guarantee 13 We reserve the right to change the design and technical data contained in our documentation without notifying our customers IBR is not obliged to notify changes of the products to previous buyers IBRit is a registered trademark ...

Page 3: ...e by the address number sender one communication control word and a double checksum The special data coding and the direct communication between PC and the radio modules on the gauges guarantee absolute data security A transmission error i e caused by a radio interference is detected by the communication protocol between PC and gauge radio module The data transmission is automatically repeated wit...

Page 4: ...3 Technical Data Mechanical Characteristics Case Plastic Wall holder Wall holder for plugging in the IBRit rf1 usb The wall holder contains two holes for the mounting with screws Dimensions with antenna W x H x D Weight 47 x 275 x 30 mm ca 175 g Electrical Characteristics Power supply By USB port Current consumption max 40 mA Measurement data Transmission frequency 433 926 MHz Frequency range 15 K...

Page 5: ...nd operating system Windows 98 ME 2000 XP 2 3 Installation of the USB driver for the IBRit rf1 usb module a Please insert the delivered CD Rom in the drive of your PC and connect after that the IBRit rf1 usb module to your USB port b The PC automatically detects that a driver must be installed and opens the following window Please confirm with OK c A new windows for the input of the driver destina...

Page 6: ...ow the window of step d becomes visible again By clicking the OK Button the installation is started 2 4 Function test of the IBRit rf1 radio modules with the programme IBR_SimKey 1 Installation of IBR_SimKey a Please insert the delivered CD into the CD Rom drive b The window for selecting the software is opened Please click onto the disc symbol of IBR_SIMKEY in the selection window ...

Page 7: ... IBR_SimKey folder z B C IBR_SimKey and start the programme IBR_SimKey EXE On the first start after the installation the programme IBR_SimKey automatically opens the window for device and gauge selection Pleases select USB as PC Connection and after that IBRit rf1 as IBR Instrument Note If after IBRit rf1 a appears then the IBRit rf1 module was not found i e no driver installed the IBRit rf1 is us...

Page 8: ...cular PC radio station can be deactivated or activated This programming possibility allows the parallel operation of several PC radio stations with up to 120 gauge radio modules By clicking on the OK Button the settings are stored and the window is closed The display window of IBR_SimKey is opened and the measurement data transmission can be started By pressing the data key of the gauge or gauge m...

Page 9: ... for programming the gauge radio modules For Programming please select the particular command and after that the parameter With the click on the OK Button the command is set into waiting queue Please press now on the gauge radio module which should be programmed the data key for transmitting a measurement value After the measurement value transmission the PC radio module sends the command from the...

Page 10: ...eep tones Confirmation 1 x green 1 x short Measurement value was transmitted successfully 1 x red 2 x short Error on radio transmission 2 x red 2 x short Timeout Error on reading the measurement value from the gauge 3 x red 2 x short Spike on the data line of the Opto RS232 4 x red 2 x short No Stopbit from the Opto RS232 interface 5 x red 2 x short Parity Error from the Opto RS232 interface 6 x r...

Page 11: ...permitted only with the prior written consent of IBR Messtechnik GmbH Co KG and must be carried out by competent staff Opening the case or tampering with the device without prior permission will lead to the loss of the guarantee and free the producer from all liabilities Before opening the instrument make sure to effectively cut the power supply e g by disconnecting the power cable 7 Before cleani...

Page 12: ...llation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by ...

Page 13: ...dling Disregard of operating instructions Tampering by unauthorised staff Attempts by any unauthorised person to repair the instrument In no case any consequences are covered by the guarantee which are connected either directly or indirectly to the instrument or its use Notice If returning the instrument under guarantee please use the original packaging Should you detect an irregularity of any kin...

Reviews: