background image

 

 

 

 

1.

 

CHARACTERISTICS AND FUNCTIONS 

 

The high-quality MM-155 finger pulse oximeter is designed for quick and non-invasive measurement 
of pulse and blood saturation in both adults and children over four years of age. By monitoring the 
saturation of hemoglobin with oxygen, various types of diseases and infections can be detected. For 
easier and more accurate measurement, our company offers you a pulse oximeter that measures 
both saturation and heart rate. It is extremely simple and convenient to use - just put it on your 
finger and press one button. 

It is a completely non-invasive and painless test that anyone can do on their own. It is enough for the 
patient to put one of the fingers into the sensor for diagnosis, and the display screen after a few 
seconds will show the directly measured value of the oxygen saturation of hemoglobin and the pulse. 

• Measurement of blood oxygen saturation (SpO2).

 

• Heart rate 

measurement. 

• Pulse intensity indicator.

 

• Bar and wa

ve graph - display of heart rate. 

• Clear, color, high

-quality TFT display. 

• Change the display direction.

 

• Convenient an

d easy one-key operation. 

• Fast measurement.

 

• Small size, light, easy to carr

y. 

• Very low battery consumption.

 

• Automatic switch

-off after 5 sec. 

• Lanyard.

 

 

CAUTION

MESCOMP TECHNOLOGIES reserves the right to make changes to the hardware and software 
resulting from technological progress. 
 

 

 

2.

 

PLEASE READ BEFORE TURN ON THE DEVICE 

 

Please read the manual carefully before using this equipment. 

Failure to follow these instructions could result in: 

• 

measurement irregularities, 

• damage to equipment,

 

• personal injury.

 

 

CAUTION:

 

 
The warranty for the devices does not cover damage from improper use, incompatible with the 
user manual. 

 

Summary of Contents for MM-151 OXYone

Page 1: ...USER MANUAL PULSE OXIMETER MM 151 OXYone THANK YOU FOR BUYING OUR BRAND PRODUCTS WE WISH YOU A PLEASANT USE BEFORE USING THE DEVICE FOR THE FIRST TIME PLEASE READ THE USER MANUAL ...

Page 2: ...łąd Nie zdefiniowano zakładki 6 PRINCIPLES OF OPERATION OF THE PULSOXYMETER 6 7 TECHNICAL SPECIFICATION 7 8 DEVICE DESCRIPTION 8 9 INSTALLATION OF LANYARD 8 10 INSTALLATION OF BATTERIES 8 11 TAKING THE MEASUREMENT 9 12 CLEANING AND DISINFECTION 9 13 SOLUTIONS OF EASY TROUBLES 10 14 STANDARDIZED MARKINGS 10 15 EMC DECLARATION Błąd Nie zdefiniowano zakładki ...

Page 3: ...reen after a few seconds will show the directly measured value of the oxygen saturation of hemoglobin and the pulse Measurement of blood oxygen saturation SpO2 Heart rate measurement Pulse intensity indicator Bar and wave graph display of heart rate Clear color high quality TFT display Change the display direction Convenient and easy one key operation Fast measurement Small size light easy to carr...

Page 4: ...when the pulse waveform is normalized and the pulse waveform on the screen is even and stable Contact your doctor if the device is working properly and the indications are outside the norm Clinical limitations Factors that may cause inaccurate measurements o Poor heart rate Significant pulsating blood flow is required for correct measurement If you have a poor pulse due to shock low ambient body t...

Page 5: ...onfiguration on your own Except as described in the manual SOLUTIONS OF EASY TROUBLE section CAUTION Do not repair the unit yourself Necessary repair and maintenance work must ONLY be performed by qualified service engineers Users are not allowed to maintain or repair the device themselves It is recommended that the sensor is not continuously applied to the same finger for more than 2 hours Contin...

Page 6: ...environment Temperature 40 C 60 C Relative humidity 95 Atmospheric pressure 500HPA 1060hPa b Work environment Temperature 10 C 40 C Relative humidity 75 Atmospheric pressure 700 hPa 1060 hPa 5 PRINCIPLES OF OPERATION OF THE PULSOXYMETER The finger pulse oximeter is used to measure blood saturation i e SpO2 oxygenation and pulse in real time It allows you to examine the level of hypoxia in the body...

Page 7: ...nm 6 75mW Heart rate measuring range 30bpm 250bpm Heart rate resolution 1 bpm Measurement accuracy 2 70 100 PR Measuring range 25 250 strokes min PR accuracy 2 bpm Resolution SpO2 1 Ambient light resistance 1 Battery type 2 x 1 5V AAA alkaline Power consumption less than 30 mA Product size 57 x 31 x 32mm Product weight 50g with batteries Package contents device pulse oximeter lanyard manual in pol...

Page 8: ... end of the rope through the first and tighten it Rys 3 Installation of lanyard 9 INSTALLATION OF BATTERIES 1 Insert the two AAA batteries correctly in the right direction 2 Replace the cover Rys 4 Installation of batteries CAUTION Be careful when inserting the battery as incorrectly inserting it may damage the device ...

Page 9: ...ing diode should be on the same side 3 Press the switch button on the front panel once 4 Do not swing your finger and stay calm Do not make any movements during the measurement 5 Get information directly from the screen 6 The On button see Rys 2 has three functions a When the device is turned off pressing the button can open it b When the device is turned on a short press of the button can change ...

Page 10: ...ZED MARKINGS The CE symbol means that this product has undergone an appropriate conformity assessment procedure and meets the essential safety health environmental and consumer requirements Follow the user manual The presented symbol the crossed out image of a wheeled bin in accordance with Directive 2012 19 EU WEEE indicates the recommendations in force in the European Union regarding separate co...

Page 11: ...evice Mescomp Technologies S A Ul Meksykańska 6 Lok 102 03 948 Warszawa Tel 48 22 636 20 00 mescomp pl mesmed pl Service office 03 948 Warszawa Ul Meksyńska 6 lok 102 E mail mescomptel mescomp pl tel 48 22 838 63 38 opening hours 7 30 15 30 date of actualization 12 03 2020 r ...

Reviews: