background image

QUICK START

1

 Install a 9-Volt Battery 

[not included]

2

 Enter 

1-2-3-4-5-6-7-8-#

3

 Turn handle before the 

green

 

light turns off

4

 To lock your safe, close door & turn

 handle back to the locked position

 

IMPORTANT : Always make sure your safe is locked before walking away!

 If your code is correct a 

green

 light will turn on for approximately 

5 seconds

 

& you will also hear a ‘

Click

 If the code is incorrect, a 

red

 light will turn on, followed by 

5

 ‘

Beeps

 

NOTE : Be sure to press firmly & ONLY use your finger tips to press the 

keys on the keypad. DO NOT USE your finger nail, a pen, etc. This will 
damage the keys.

SAFE OPERATION & PROGRAMMING

1

st

 USER CODE 

is factor y set to :

 

1-2-3-4-5-6-7-8

2

nd

 USER CODE 

is factor y set to :

 

1-6-8 

 

IMPORTANT : Because the codes are factory set, we highly recommend 

changing the codes to your own unique codes immediately!

HOW TO OPEN YOUR SAFE

1

 Input : 

Code

 - 

[light stays green for 

5 seconds]

2

 Turn the handle to the unlocked position before the 

green

 light disappears

 

Example : 

1-6-8-#

 Invalid Code: 

5

 ‘

Beeps

Wrong Tr y Penalty

If 

3 wrong codes

 are entered consecutively, the keypad will 

shut down

 for 

a period of 

15 minutes

. During this 

shut down

 period, the keypad will not 

accept any codes.

CHANGING THE 1

ST

 USER CODE 

[Code length: 1-8 digit code]

 

NOTE : 

Test the new codes several times before closing the door.

1

 Locate the red button on the inside hinge side edge of the door

2

 Press the red button 

[Lock will ‘

Beep

’ 

2 times

 with the 

yellow

 light on]

3

 Input : Your 

New Code 

*

 

[lock will ‘

Beep

’ 

2 times]

 Unsuccessful Code Change : 

5

 ‘

Beeps

’ [old code is still valid; repeat 1 - 3]

PG.3

  

|

  

MSC SERIES MSL-50-

P

 ELECTRONIC LOCK INSTRUCTIONS