How to mount the ARGUS 360
unwanted heat sources being detected. Leave a distance of at least
5 m (Figure
§B
).
– Mount the lighting which is to be switched by ARGUS 360 above it,
not below it (Figure
§C
).
– ARGUS 360 has type of protection IP 55 and is therefore suitable for
use in outdoor areas as well. To make sure that the lighting is not
switched on by environmental influences, make sure that ARGUS is
sheltered from rain and direct sunlight if possible (for example,
raindrops running down the lens could cause the movement detector
to switch) (Figure
$
).
– If you are installing several movement detectors, make sure that the
areas of detection of the individual detectors overlap (Figure
%
).
Further information can be found in the "Merten Technical Information", in
the section "ARGUS movement detector".
¼
Risk of electrocution
ARGUS 360 may only be installed and connected by professional
electricians. Please observe the relevant regulations in your own
country.
¼
Risk of electrocution
The output may carry an electrical current even when the load is
switched off. Always disconnect the fuse in the incoming circuit
from the supply before working on connected loads.
1
Open the condensation water opening (Figure
&
).
2
Open the cable routing opening (Figure
/
).
3
Use the screws supplied to mount the ceiling housing direct on the
ceiling (
Figure
(A
) or in the ceiling installation box (
Ø
60 mm,
Figure
(B
) in such a way that the area of detection required (16 m to the
front + 14 m to the rear and 20 m across) corresponds to the imprint
on the ceiling housing.
How to mount the ARGUS 360
V5644-581-01.book Seite 11 Donnerstag, 24. November 2005 1:29 13
12
How to install the electrical connection
Figure
)
:
1
Strip the connecting cable insulation by a length of 11 mm.
2
Insert the external conductor into terminal "L".
3
Insert the neutral conductor into terminal "N".
4
Insert the connected external conductor into terminal "
↓
".
"Through-wiring" to other loads is permitted. Release the terminals by
pulling and turning the conductor at the same time.
|
Note
When switching inductive loads such as transformers, relays,
contactors or fluorescent lamps, spikes occur which could lead to
the load being switched on again ("maintained light effect").
Connect a capacitor (542895) parallel to the inductive load in order
to reduce these spikes.
Installation options (Figure
=
):
A
ARGUS constantly connected to the mains:
ARGUS monitors its area constantly.
B
ARGUS combined with two-way switch:
depending on the switch position, either maintained light or
automatic mode.
C
ARGUS combined with break contact:
ARGUS is always ready for operation. By pressing the push-button
(the power is briefly disconnected for 2–3 seconds), ARGUS is
switched on for the set time. Every further movement increases
the switching duration.
D
ARGUS parallel:
several ARGUS devices working together can switch a lamp group
when the maximum switching capacity of
one
device is not
exceeded. To achieve this, you must reduce the sensitivity of the
devices. For technical and functional reasons, we do not advise
forming larger device groups using more than four ARGUS
devices.
How to install the electrical connection