ELEC
TRIC
AL
CIR
CUIT
S
14
15
16
17
18
19
20
21
22
23
24
25
26
12
11
10
9
8
7
6
5
4
3
2
1
13
SRB Terminal Locations:
24.4
X3 - Output for e4 Convection Fan Controller.
1
X101 - Voltage Selection Relay coil feeds.
2
X18b - Air intake Filter Reed Switch.
3
X18e - Right Magnetron Thermostat.
4
X18d - Left Magnetron Thermostat.
5
X18c - Cavity Overheat Thermostat.
6
X18a - On/Off Switch.
7
X14 - Cavity Temperature Thermocouple.
8
X5 - Fan RPM Input.
9
X13 - P Bus, Ethernet Port.
10
X12 - C Bus, Development PC Port.
11
X11 - P/C Bus, BTS Cable.
12
X1 - 24V supply from Low Voltage Transformer.
13
X8 - Cooling Fan.
14
X17 - Not used.
15
X20 - Microwave Stirrers.
16
X9 - Mains Output, Convection Fan Controller.
17
X103.1 - Mains Output to Low Voltage
18
Transformer.
X103 - Mains Input, Live & Neutral.
19
X2.1 - Mains Input, Live for Heaters.
20
X2.2 - Mains Output, Live to Heaters.
21
X102a - Mains Input, Neutral for Magnetron
22
Transformers & Monitor Door Switch.
X102b - Mains Output, Neutral to Magnetron
23
Transformers & Monitor Door Switch.
X4a - Door Switch signal from Secondary Door
24
Switch (Live for Magnetron Transformers).
X10 - Connector Block for door switches.
25
X4b - Live for Magnetron Transformers.
26