background image

INSIDE

Step 22

22A

INSIDE

Fit bottom door seal keeping angled fin to inside. Notch fin where it meets the closing 

seal to ensure door closes fully.

22C

22B

INSIDE

Step 21

15

16

INSIDE

MGVC33A

Drill with 6mm masonary

drill bit.

MG6x30PLUG

Level the rail.

Mark outline of the 

wall bracket.

Step 23

Fix the top rails.

A

B

Left and right hand seal kits (A) are provided, determine handing and use appropriate 

seal kit.

Left hand model shown below. Push on longest seal between hinges onto back edge 

of moving panel. Take shortest seal and fit to top keeping notch to hinge.

Repeat with longer bottom seal.
Fit closing seal (B) to edge of the inline panel. Make sure to keep fin to the inside.

 

Fix the wall bracket.

23A

23B

23C

23D

23E

23F

Summary of Contents for ARYSTO COLOUR

Page 1: ... 1576 www merlynshowering com To download the Declaration of Performance DOP for this product please use the link below https merlynshowering com aftersales support dop certs MERLYN Merlyn Industries Ltd MER01 20 EN 14428 Shower enclosures with aluminium profiles and safety glass Cleanability Impact resistance shatter properties Pass Pass Durability Pass Declaration of performance number CEARH1 2 ...

Page 2: ...45 Installation tool 1 4 MG8x51PLUG x4 MGST5X65 AC34 AC35 AC25SPACER 1 1 2 AC13 x4 AC14 x2 A06S0046 2 8S1300511 1 AC07 x1 Bracing bar Wall plug x4 4 30 screw 4 4mm Hex key 2 2 Clamp cover cap x4 Wall bracket cover cap x4 AC10 Covercap x4 Spacer x 2 ...

Page 3: ...15 16 17 GMGHFA MGVC44LSET RSET 1 MGVC30A MGST5X65 1 AC07 GMGCPA GMGDPA B C D AC14 AC01 AC34 AC37 AC10 AC35 Put bottom track in place on the tray insert bottom brackets to both ends Attention Keep the sloped side of bottom profile to outside Step 2 AC03SL AC04SL Step 1 IMPORTANT Whether fitting on a tray or on a tiled Wetroom the tray or floor must be 100 level 100 level 2A 2B ...

Page 4: ...and the closing side fixed panel no notch cuts Step 5 Push on wall profile completley ensuring end is flush with the top of the glass panel Top 250mm Bottom 275mm THIS WAY UP THIS WAY UP Hinged fixed panel Closing side fixed panel Top 250mm Bottom 275mm 0 15mm Adjustment 0 15mm Adjustment Position the track parallel to the tray edge while ensuring the gap between the ends of the track and the insi...

Page 5: ... the hole in the glass IMPORTANT This is critical as it is where the panel adjusts If the brackets are not positioned in the center adjustment will be affected Lift the assembled panels into the track Plumb each panel and mark the centre of each slot A Place the assembled bottom track back on the tray and place fixed panel into the track Fix wall brackets Do not fully tighten leave enough slack fo...

Page 6: ...it hinges to inline panel ensuring that the part of the hinge which has a notch will be on the moving panel side Inline Panel Screw 5 65 Tip Use MDF tool for squaring hinges Remove back plates from hinges on moving panel side and place hinge plate washers bolts and hex key inside enclosure PVC spacer A To help align the hinge place the 2mm clear PVC spacer under the hinge on the edge of the cutout...

Page 7: ...inges ensuring washers are in position and hinges are level INSIDE 15B Use door assembly tool to hold the door in place until the hinges are fitted locating aids Step 14 Place locating aids and spacers on threshold one each side of opening Standing inside the enclosure lift the door onto the locating aids Make sure you have all the fixings and tools required inside the enclosure SP010SP281000 15A ...

Page 8: ... panel Door panel Remove top holding strip To remove door positioning aids open door outwards When positioning aids have been removed check gap beneath door is even If gap is not equal loosen hinges slightly and adjust Measure between edge of fixed panel and the wall and cut infill seal to this length Apply a dab of silicone to both ends insert to bottom profile Note The vertical fin should be pos...

Page 9: ...tline of the wall bracket Step 23 Fix the top rails A B Left and right hand seal kits A are provided determine handing and use appropriate seal kit Left hand model shown below Push on longest seal between hinges onto back edge of moving panel Take shortest seal and fit to top keeping notch to hinge Repeat with longer bottom seal Fit closing seal B to edge of the inline panel Make sure to keep fin ...

Page 10: ...an achieve this by loosening the screws fixing the plate hinge to the wall and the bolts clamping the bracket hinge to the glass Adjust the panels until the desired fit is achieved Fully tighten all fixings Note If not further adjustment is needed make sure all fixings have been tightened securely 24A INSIDE INSIDE INSIDE Where an angled bracing bar is fitted additional adjustment can be made by 1...

Page 11: ...e including where the bottom track meets the end brackets Sealing your enclosure 24 h 19 Make sure all surfaces are thoroughly cleaned and dry before applying sealant Merlyn Industries Ltd MER01 20 EN 14428 Shower enclosures with aluminium profiles and safety glass Cleanability Impact resistance shatter properties Pass Pass Durability Pass Declaration of performance number CEARH1 2 ...

Reviews: